Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles: DFG German National Licenses  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Der Ophthalmologe 95 (1998), S. 176-180 
    ISSN: 1433-0423
    Keywords: Key words Cyclophotocoagulation • Diode laser • Ultrasound biomicroscopy ; Schlüsselwörter Zyklophotokoagulation • Diodenlaser • Ultraschallbiomikroskop
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Um die therapeutische Effektivität der Glaukomtherapie mittels Diodenlaserzyklophotokoagulation zu evaluieren, wurden die intraokularen Tensionswerte (IOP) nach Zyklophotokoagulation an 106 Augen 8–24 Monate postoperativ erfaßt. Methode: 24–30 Laserherde mit einer Energie von 2,8–3,6 J wurden mittels Fokussieroptik 1,5 mm hinter dem Limbus zirkulär über 360 ° gesetzt. 25 der operierten Augen wurden postoperativ ultraschallbiomikroskopisch auf Ziliarkörperveränderungen untersucht. Ergebnisse: Der mittlere IOP sank von präoperativ 25,0 ± 5,7 mm Hg auf 18,0 ± 6,0 mm Hg langfristig postoperativ. Eine erfolgreiche Tensionsregelung (IOP 〈 22 mm Hg bzw. dauerhafte Schmerzfreiheit bei funktionslosen Augen) wurde bei 85 % der Augen erreicht, wobei bei 23 Augen mehr als 1 Zyklophotokoagulation durchgeführt werden mußte und 6 Augen wegen der Notwendigkeit einer anderen tensionsregulierenden Operation aus der Studie ausschieden. Es traten keine schwerwiegenden Komplikationen auf. Die morphologischen Untersuchungen zeigten bei 22 von 25 Augen eine temporäre postoperative Ziliarkörperschwellung und bei 8 Augen eine temporäre Ziliarkörperabhebung. Schlußfolgerung: Die Zyklophotokoagulation mit dem Diodenlaser führt bei verschiedenen Glaukomarten risikoarm auch langfristig zu einer effektiven IOP-Senkung. Morphologisch zeigt sich postoperativ eine entzündliche Reaktion im Ziliarkörper, deren Ausmaß nicht mit der Höhe der Tensionssenkung korreliert.
    Notes: Summary To assess the clinical effectiveness of glaucoma therapy with diode laser cyclophotocoagulation, 106 eyes (51 eyes with primary open-angle glaucoma, 22 eyes with secondary glaucoma, 10 eyes with narrow-angle glaucoma, 23 eyes with other glaucomas) of 87 patients were treated. Using a diode laser coupled with a fiberoptic probe, ending in a focusing tip, all eyes were treated with 24–30 spots over 360 ° and 2.8–3.6 J of energy, 1.5 mm posterior to the limbus. The intraocular pressure was obtained over a period of time until 8–24 months after operation. Additionally, morphological changes of the ciliary body were observed in 25 eyes by means of ultrasound biomicroscopy. Results: The IOP decreased from a baseline mean of 25.0 ± 5.7 mm Hg to 17.6 ± 5.3 mm Hg directly after operation and increased sligthly to 18.0 ± 6.0 mm Hg in the following 24 months. Successful control of IOP (IOP constantly 〈 22 mm Hg or pain relief in blind eyes) occurred in 90 of 106 eyes (84.9 %). In 23 eyes more than one treatment was given. In 6 eyes another IOP-reducing operation had to be performed. In 19 eyes slightly elongated intraocular inflammatory reactions were seen, without any serious complications. The morphological investigations showed in 22 of 25 cases temporary edema of the ciliary body. A temporary detachment of the ciliary body was seen in 8 eyes. Conclusions: Diode laser cyclophotocoagulation is an effective and safe procedure to reduce IOP in different types of glaucoma over a long time. Postoperatively, a temporary inflammatory reaction of the ciliary body was observed with no correlation to the degree of reduction of the IOP.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...