    Electronic Resource
    Electronic Resource
    Springer
    Intensive care medicine 14 (1988), S. 658-660 
    ISSN: 1432-1238
    Keywords: CPAP ; Turbine ; High flow ; Work of breathing ; Mobile
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A continuous high flow CPAP system incorporating a turbine blower is described. The system achieves inspiratory flow rates of 150l/min or more by means of reticulated gas flow and inspired oxygen fractions of 0.21–0.95. Positive airway pressure is provided by weighted disc valves and a modified aviationtype CPAP face mask provides electronic communication with the patient. The mobility of the system also enables its use as an intermittent physiotherapy aid. Work of breathing of the system, as assessed by total pressure fluctuations, is at a minimum.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 6 (1979), S. 91-97 
    ISSN: 0306-042X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A new technique is reported resulting in the direct, instantaneous analyses of trace compounds in breath. The analyses were performed using a commercial atmospheric pressure chemical ionization mass spectrometer (TAGA TM 2000 APCI mass spectrometer). A known flow of breath sample is introduced into the ionization region of the mass spectrometer. The study includes the measurement and monitoring in real-time, of breath ammonia during a 24 hour and a 48 hour period. The ammonia profiles indicate a personalized daily pattern associated with each subject. This method appears to be of potential value in routine detection and treatment of hyperammonemia patients. Results also show that it is possible to obtain instantaneous analyses of several naturally occurring metabolites and other substances on breath in the ppm to ppt range, suggesting a number of diagnostic research applications.
    Additional Material: 9 Ill.