Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles: DFG German National Licenses  (4)
  • 1995-1999  (4)
  • Chemistry  (3)
  • Polymer and Materials Science  (3)
  • Key words Idiopathic scoliosis  (1)
  • Biochemistry and Biotechnology
Source
  • Articles: DFG German National Licenses  (4)
Material
Years
Year
  • 1
    ISSN: 1432-0932
    Keywords: Key words Idiopathic scoliosis ; Dorsal spondylodesis ; Surgical ; technique
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The radiographic and clinical outcomes and complications among two groups of adolescent patients treated for idiopathic thoracic scoliosis with dorsal instrumentation using a unified implantation system (Universal Spinal System) were compared retrospectively. A total of 69 patients were included in the study. In 30 patients an intraoperative correction of the scoliosis was performed by translation and segmental correction (translation group, Helsinki). In 39 patients the correction was achieved according to the Cotrel-Dubousset rod rotation maneuver (rod rotation group, Berlin). The goal of the present study is to investigate whether one of the operative procedures leads to a better correction of idiopathic adolescent thoracic scoliosis than the other. The mean follow-up interval was 30 months, with a minimum of 12 months. There were no significant preoperative differences in age (15 ± 2 years in both groups), gender, or type of scoliosis (King types 2, 3, and 4). The preoperative radiographic measurements showed no significant differences between the two groups. In both patient groups, the thoracic primary curve, the lumbar secondary curve and the thoracic apical rotation were improved by the operation. Lumbar apical rotation and the sagittal profile were unchanged in both groups. The thoracic primary curve was corrected from 50°± 6° to 24°± 7° in the translation group and from 54°± 11° to 22°± 11° in the rod rotation group. The extent of the correction of the thoracic curve was significantly greater in the rod rotation group than in the translation group (59% vs 52% correction). In contrast, the translation procedure seems to have a more beneficial effect on spinal balance than rod rotation. Neurological complications did not occur. In both patient groups an increase in the non-instrumented lumbar curve was noted, in two cases each. In three patients from the rod rotation group the instrumentation had to be removed due to a late infection with negative microbiological results.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0021-9304
    Keywords: poly(DL-lactide-ε-caprolactone) ; degradation ; foreign body reaction ; subcutaneous implant ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The aim of this study was to evaluate the degradation and foreign-body reaction of poly(DL-lactide-ε-caprolactone) (PLA85CL50) bars. This specific biomaterial is used for the construction of nerve guides, which can be used in the reconstruction of short nerve gaps. Subcutaneously implanted PLA85CL50 bars were harvested after implantation periods ranging from 3 to 12 months and evaluated for the rate of degradation and the degree of foreign-body reaction. It was observed that this copolymer degraded completely within 12 months and that no lactide or ε-caprolactone crystals were formed. Furthermore, we conclude that the foreign-body reaction of PLA85CL50 is very mild. These properties make the amorphous copolymer of DL-lactide and ε-caprolactone (50:50) suitable for the construction of nerve guides. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 36, 337-346, 1997.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: One of the ways to reconstruct a nerve defect is to use a biodegradable nerve guide. The aim of this study was to establish a nerve guide constructed of an amorphous copolymer of lactic acid-caprolactone. A pilot study was set up to elucidate the effect of the tube dimensions on nerve regeneration. Four types of nerve guides, with internal diameters ranging from 1.12-1.23 mm and wall thicknesses ranging from 0.34-0.68, were tested for this purpose. We evaluated the biodegradation, foreign body reaction and nerve regeneration by light microscopy, after three different implantation times (1, 2, and 3 months). After 2 months, we observed that all types of nerve guides had changed from a transparent to an opaque and swollen state, and that they had lost their strength. The foreign body reaction was characterized by the presence of giant cells and fibroblasts surrounding the degrading nerve guide. From this pilot study, we conclude that nerve guide type 1, with an internal diameter of 1.23 mm and a wall thickness of 0.34 mm, can ensure nerve regeneration in the case of a 1-cm gap in the sciatic nerve of the rat. Nerve guides types 3 and 4, with relatively small lumens, show nerve compression due to a more pronounced swelling of the degrading tube. © 1995 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The aim of this study was to evaluate short-term peripheral nerve regeneration across a 10-mm gap, using a biodegradable poly(DL,-lactide-ε-caprolacton) nerve guide, with an internal diameter of 1.5 mm and a wall thickness of 0.30 mm. To do so, we evaluated regenerating nerves using light microscopy, transmission electron microscopy and morphometric analysis after implantation of 12-mm nerve guides in the sciatic nerve of the rat. Evaluation times ranged from 3-10 weeks. Three weeks after reconstruction, myelinated nerve fibers could be observed in the distal nerve stump. Ten weeks after reconstruction, the regenerating nerves already resembled normal nerves. In conclusion, we show that poly(DL,-lactide-ε-caprolacton) nerve guides can be successfully applied in the reconstruction of severed nerves in the rat model. Furthermore, we have observed the fastest nerve regeneration described thus far, after reconstruction using a biodegradable nerve guide. © 1996 John Wiley & Sons, Inc.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...