    Springer
    Journal of materials science 17 (1982), S. 580-588 
    ISSN: 1573-4803
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract Continuous amorphous wires with high strength and good ductility have been produced in the Fe-P-C alloy system by the in-rotating-water spinning technique; however, no amorphous wires are formed, using the same technique, in the Fe-P-B, Fe-P-Si and Fe-B-C systems. The Fe-P-C amorphous wires have a circular cross-section, smooth peripheral surface, and diameters in the range of about 80 to 230μm. Their tensile strength,σ f, and Vickers hardness,H v, increase with increasing phosphorus and/or carbon content and reach 3000 MPa and 895 DPN for Fe75P10C15. Fracture elongation,ε f, including elastic elongation is about 2.8%. Cold-drawing to an appropriate reduction in area causes an increase inσ f andε f of about 3.7 and 79%, respectively. This increase is interpreted to result from an interaction between crossing deformation bands introduced by cold-drawing and the increase in the uniformity of shape for the drawn wires. Further, the undrawn and drawn amorphous wires are so ductile that no cracks are observed even after a sharp bending test. Thus, the Fe-P-C amorphous wires are attractive for fine-gauge high-strength materials both because of the uniform shape of the wires and because of their superior mechanical qualities.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-4803
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract This paper presents the Young's modulus of Fe100−x−y Si x B y , Fe100−x−y P x C y , Co100−x−y Si x B y , Pd77.5Cu6Si16.5, Pd48Ni32P20 and Pt60Ni15P25 amorphous wires determined from the Young's modulus sound velocity measurement. With increasing metalloid content, the Young's modulus increases from 1.58×1011 to 1.87×1011 N m−2 for Fe-Si-B, from 1.40×1011 to 1.52×1011 N m−2 for Fe-P-C and from 1.73×1011 to 1.75×1011 N m−2 for Co-Si-B systems. The increase in Young's modulus with the amount of metalloid elements is the largest for B, followed by Si, C and then P. The Young's modulus of Fe- and Co-Si-B amorphous wires increases significantly with the replacement of iron or cobalt by IV–VII group transition metals. It was recognized that there existed a strong correlation between Young's modulus (E) and tensile fracture strength (σ f); the ratio of σ f to E is approximated to be 0.02 for all the amorphous wires investigated. These results imply that the Young's modulus is dominated mainly by the structural and compositional short-range orderings due to the strong interaction between metal and metalloid atoms which hinders the internal displacements. The existence of a constant ratio for σ f/E was interpreted to originate from a common mechanism for plastic flow of the amorphous wires. Further, it was noted that the Young's modulus of the Fe- and Co-based amorphous wires with diameters of ≃ 100 to 120 Μm was slightly lower than that of the amorphous ribbons with thicknesses of ≃ 20 to 25 Μm. This difference was attributed to the difference in structural ordering due to the differences in the solidification processes.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Graefe's archive for clinical and experimental ophthalmology 173 (1967), S. 42-47 
    ISSN: 1435-702X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary 1 ml of Pyrifer II was daily administered to rabbits suffering from experimental herpes infection. In the course of this treatment a shortened incubation time, a prolonged healing time and a more severe process with stronger parenchyma participation and deep keratitis were noticeable in comparison with control animals. Accordingly more and stronger scars of the cornea were seen after healing.
    Notes: Zusammenfassung Bei Kaninchen mit experimenteller Herpes-Infektion der Cornea wurde täglich 1 Ampulle Pyrifer II i.v. injiziert. Unter dieser Behandlung zeigte sich im Vergleich zu Kontrolltieren eine verkürzte Inkubationszeit, eine verlängerte Abheilungszeit und ein schwererer Verlauf mit stärkerer Parenchymbeteiligung und tiefer Keratitis. Entsprechend waren mehr und stärkere Hornhautnarben nach Abheilung sichtbar.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1573-4803
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract Interlaminar tensile shear tests are conducted to study the degradation mechanisms of electron irradiated glass or carbon cloth reinforced epoxy laminates. Interlaminar shear strength decreases significantly after the dose exceeds 3000 Mrad for glass/epoxy, but remains constant up to 12 000 Mrad for carbon/epoxy. SEM photos reveal that debonding of glass fibres and epoxy matrix (or degradation of silane coupling agents) plays an important role in the dose-dependent strength reduction of glass/epoxy laminates. The decrease in the interlaminar shear strength corresponds to that in the three-point bending strength. On the other hand, the SEM fracture appearance is almost dose-independent for carbon/epoxy laminates. In addition, some preliminary irradiation tests are conducted at −120° C to observe the effects of irradiation temperatures.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Experimental mechanics 27 (1987), S. 398-403 
    ISSN: 1741-2765
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract A method is presented for fatigue design by comparing the load on the bolt in joints with the fatigue strength of the bolt-nut joints. Two types of bolted joints, cylindrical and T-flange joints, are treated as examples. Reliability concepts are introduced to the design. Fatigue tests of the above-mentioned bolted joints were also carried out to verify the applicability of the method. As a result, it appears that the fatigue behavior of threaded fasteners can be estimated to some extent by comparing the load on the bolt with the fatigue strength.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 306 (1981), S. 29-30 
    ISSN: 1618-2650
    Keywords: Trenn. von Quecksilber, Cadmium, Zink, Blei ; Chromatographie, Säulen ; P-Cellulose, HCl-Medium
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 12 (1968), S. 2639-2647 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The radiation-induced polymerization of ethylene was carried out by use of a benchscale plant with a flow-type reactor of 1 liter capacity under the following conditions: pressure, 200-400 kg/cm2; temperature, 30-90°C; irradiation intensity, 3.8 × 105 rad/hr; and ethylene flow rate, 300-3000 nl/hr. The molecular weight of polymer formed was shown to decrease with increasing reaction temperature and to increase with increasing pressure. When the ethylene flow rate increases, the molecular weight decreases in the polymerization at 30-60°C, but it does not change in the polymerization at 75-90°C. Methyl group content, which is a measure of short-chain branching of the polymer, increases with increasing reaction temperature, i.e., ca. 1 CH3/1000 CH2 at 30°C and ca. 9 CH3/1000 CH2 at 90°C. Methyl content is independent of the ethylene flow rate. The changes in the melt index of polymer with reaction conditions corresponds to the change of the molecular weight. The density, crystallinity, and melting point of polymer decrease with the reaction temperature as the short-chain branching increases, and they are almost independent of ethylene flow rate and pressure.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...