Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles: DFG German National Licenses  (1)
  • 1985-1989  (1)
  • 1950-1954
  • 1940-1944
  • Measurement techniques: blood pressure, continuous, noninvasive pulse oximetry  (1)
Source
  • Articles: DFG German National Licenses  (1)
Material
Years
  • 1985-1989  (1)
  • 1950-1954
  • 1940-1944
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of clinical monitoring and computing 5 (1989), S. 221-228 
    ISSN: 1573-2614
    Keywords: Monitoring: blood pressure oxygen saturation ; Equipment: Pulse oximeters finger blood pressure monitor ; Measurement techniques: blood pressure, continuous, noninvasive pulse oximetry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science , Medicine
    Notes: Abstract Pulse oximeter arterial hemoglobin oxygen saturation (SpO2) and finger arterial pressure (FINAP) were continuously monitored before, during, and after cardiopulmonary bypass in 15 male patients. SpO2 was monitored simultaneously with two pulse oximeters, a Nellcor N-100 and an Ohmeda Biox III. The readings obtained from the two pulse oximeters were compared with arterial blood measurements obtained using a CO-oximeter. FINAP was monitored by a prototype device (Finapres) based on the Peňaz volume-clamp method. FINAP was correlated with intraarterial pressure (IAP). Both pulse oximeters functioned well before cardiopulmonary bypass. The correlations with CO-oximeter values were 0.927 for the N-100 and 0.921 for the Biox III. Immediately after the onset of cardiopulmonary bypass, the N-100 pulse oximeter stopped displaying values. The Biox III pulse oximeter continued to display values during the cardiopulmonary bypass period; the correlation with CO-oximeter values was 0.813. After cardiopulmonary bypass, the N-100 began displaying values in 2 to 10 minutes. After cardiopulmonary bypass the correlation with CO-oximeter values was 0.792 for the N-100 and 0.828 for the Biox III pulse oximeter. The Finapres finger blood pressure device functioned well in 13 of 15 patients before cardiopulmonary bypass. The mean bias ± precision of FINAP-IAP for mean pressure was 8.3±10.2 mm Hg (SD) and the correlation coefficient was 0.814. During cardiopulmonary bypass, the Finapres device functioned well in 10 of 15 patients. The mean bias precision of FINAP-IAP, for mean pressure in these 10 patients was 6.6±8.7 mm Hg and the correlation coefficient was 0.902. Immediately after cardiopulmonary bypass, the Finapres functioned well in 11 of 15 patients. The mean bias ± precision of FINAP-IAP for mean pressure was 8.6±14.1 mm Hg and the correlation coefficient was 0.533. This study documented that devices for continuous noninvasive monitoring can usually function well under the extreme conditions seen during open-heart surgery. Pulse oximeters may find a place in the monitoring of patients during open-heart surgery, although they cannot totally replace the invasive techniques. Under the conditions of diminished pulsatile peripheral blood flow we observed some differences between the two pulse oximeters.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...