Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles: DFG German National Licenses  (2)
  • 1985-1989  (2)
  • 1915-1919
  • 201Tl  (1)
  • 99mTc-MIBI  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European journal of nuclear medicine 11 (1986), S. 413-416 
    ISSN: 1619-7089
    Keywords: 201Tl ; Thyroid nodules ; Scintigraphy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We performed 201Tl thyroid scintigraphy using an early and delayed scanning technique in 34 patients exhibiting cold nodules on 99mTc scans. Of the 29 benign nodules, 27 were correctly diagnosed as being negative, i.e. 93% specificity. However, two of five malignant nodules failed to concentrate activity on both the early and delayed scans. The low sensitivity (60%) of this method for detecting carcinomas limits its clinical value in the routine, diagnostic work-up of patients with suspected thyroid cancer. Our findings are in contrast to previous more optimistic reports.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1619-7089
    Keywords: Contraction fraction ; 99mTc-MIBI ; SPECT ; Myocardial size ; Radionuclide ventriculography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Criteria for the detection of coronary artery disease in nuclear cardiology include visualization of perfusion defects and functional impairment of contraction. The purpose of this study is to combine both methods in one procedure with the new myocardial perfusion tracer, 99mTc-methoxy-isobutyl-isonitril (MIBI), reducing time and radiation burden to the patient. Following an uncomplicated recovery, ten patients with first myocardial infarction participated in this study. Radionuclide ventriculography (RNV) was performed at rest and during exercise. Within 2–3 days, 370 MBq 99mTc-MIBI were injected and SPECT acquisition commenced 1 h later. Data processing included a scar image in polar coordinates. Areas of significantly reduced tracer uptake were expressed as a percentage of the total myocardial area. Directly following SPECT, resting and maximum exercise gated planar LAO images were recorded and the contraction was quantified. The concept of the contraction fraction (CF) rested on the end systolic change in count distribution: their increase in density and their centripetal concentration. For comparison, geometrical inner edge detection techniques were also applied. All algorithms for describing an EF equivalent were verified by computer simulations, showing a perfect correlation over a wide range of preset EFs. When applied to the patient studies only the non geometric methods revealed a good correlation with the ejection fraction (EF) obtained by RNV, and with the infarct size measured by SPECT. The corresponding correlation coefficients (r), standard errors (SEE) and the regression lines read as follows (in %): CF=0.56×EF+24.8; r=0.87; SEE=4.98; CF=-0.53×SPECT+71.5; r=0.93; SEE=4.19. Thus, estimation of the left ventricular function by the above defined CF is feasible, easy to perform and clinically meaningful. In one procedure with 99mTc-labelled MIBI not only the perfusion abnormalities were detectable, but also any reduction in function by a valied EF equivalent. Although the monochromatic gamma spectrum of the radionuclide provided better tissue penetrating power, the inner edge of the left ventricle was poorly outlined (especially in the stress studies) and does not lend itself to clinical routine practice.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability