Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles: DFG German National Licenses  (2)
  • 1985-1989  (2)
  • 44.10.+i  (1)
  • Analytical Chemistry and Spectroscopy  (1)
Source
  • Articles: DFG German National Licenses  (2)
Material
Years
  • 1985-1989  (2)
Year
Keywords
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 45 (1988), S. 87-91 
    ISSN: 1432-0649
    Keywords: 42.55.Dk ; 44.10.+i
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A small-signal gain in CO2 waveguide laser medium has been measured on rotational-vibrational transitions in the P-branch of the (0, 0, 1)-(0, 20, 0) band. It has been found that the rotational temperature is well defined in the waveguide laser system where high excitation power is injected and a large amount of energy is flowing through vibrational, rotational, and translational degrees of freedom. The rotational temperature is slightly higher than the translational temperature.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 8 (1985), S. 69-72 
    ISSN: 0935-6304
    Keywords: Thin-layer chromatography, HPTLC ; Cellulose plates ; Tryptophan-NAD pathway ; Rat urine ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: High performance thin-layer chromatography (HPTLC) was used to determine 12 metabolites of the tryptophan-NAD pathway in rat urine. The method of separation described in the previous report was improved. The metabolites were separated on the cellulose plate by using five multiple developments with four solvent systems. The plate was scanned by the TLC scanner at 254 nm and the amounts of the metabolites were calculated by comparing peak areas of the scanning curves obtained for the urine sample and for the authentic standards. This procedure can be used as a semiquantitative determination method for the metabolites in biological fluids.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...