Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles: DFG German National Licenses  (3)
  • 1980-1984  (3)
Source
  • Articles: DFG German National Licenses  (3)
Material
Years
Year
  • 1
    ISSN: 1432-2099
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Physics
    Notes: Summary Roots ofPisum sativum L. were chronically exposed to 60-Hz vertical electric fields ranging from 150 to 450 V/m in an aqueous medium whose conductivity was approximately 0.07 S/m. Control and exposed roots were grown concomitantly in the same tank whose medium was continuously circulated and maintained at 19° C. The experiments were conducted blind. Root growth rates were determined daily and the mitotic index was determined for various intervals over a 24-h period, ranging from 12 h before to 12 h after electrode energization. Root growth rates were affected in a dose dependent relationship by exposures greater than 250 V/m. Mitotic indices were not affected by 150 V/m but were affected at 350 V/m; the former exposure did not alter root growth rates, the latter did. The growth rates of vertically exposed roots were compared to those of horizontally exposed roots; the former are more sensitive at a given field strength. The observations are consistent with the postulate that the electric field acts upon the cell through a perturbation of the transmembrane potential.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 2 (1981), S. 329-340 
    ISSN: 0197-8462
    Keywords: electric fields ; 60 Hz ; biologic effects ; membrane potentials ; recovery ; Pisum sativum ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Roots of Pisum sativum L. were chronically exposed in aqueous inorganic nutrient medium to 60-Hz electric fields between 140 and 490 V/m (growth medium conductivity ∼ 0.08 S/m). The growth rate, meristematic mitotic index, and growth rate recovery of the roots were determined. At 140 V/m there was no perturbation in growth rate or mitotic index. At 430 V/m the growth rate and the mitotic index were reduced. The mitotic index had a maximum depression (∼ 55% of control), which occurred at 4 h. The depression in growth rate was immediate and constant over time. When roots were exposed to an electric field at 430 V/m for 2 days, the growth rate was depressed by about 40%. When the field was terminated, the growth rate steadily increased and was almost normal after 5 days. At 490 V/m root growth rate was almost completely arrested. According to these results, there is a narrow range of induced membrane potentials that span the range from slightly altered to almost completely arrested growth rates.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 4 (1983), S. 215-247 
    ISSN: 0197-8462
    Keywords: electric field ; 60-Hz ; detection ; psychophysics ; rats ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Rats partially deprived of food were trained individually to press a lever in the presence of a vertical, 60-Hz electric field and not to press in its absence. Correct detections that occurred during brief, 3- or 4-s trials occasionally produced a food pellet. The probability of detecting the field was found to increase as field strength increased. The threshold of detection, ie, the field strength required for detections at a probability of 0.5 after correction for errors, was generally between 4 and 10 kV/m. The range of field strengths between almost zero and almost 100% correctness of detection was approximately 8 kV/m. A logistic function provided a good description of the increase in the detection probability with increasing field strength. These performances occurred reliably in 19 rats, some of which were studied for 2 years. Control procedures showed that the behavior required that the rat be in the electric field; the behavior was not controlled by any of several potentially confounding variables.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...