Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles: DFG German National Licenses  (2)
  • 99m Tc-teboroxime  (1)
  • Chylous effusion  (1)
  • 1
    ISSN: 1619-7089
    Keywords: Thoracic duct ; Lymphoscintigraphy ; Chylous effusion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Imaging of the thoracic duct is usually performed by radiological lymphography. However, this procedure, which uses an oil based dye injected directly into the lymph channels, has some adverse effects. In this paper we note that lymphoscintigraphy, a physiological and non invasive method, may visualize thoracic duct abnormalities, and might be particularly useful when radiological lymphography is contraindicated.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-0743
    Keywords: coronary artery disease ; myocardial perfusion scintigraphy ; stress testing ; thallium-201 ; 99m Tc-teboroxime
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A series of 30 patients (25 males, 5 females, age=28–73 years) with a clinical indication of thallium-201 stress/4 hours redistribution scintigraphy has been studied using stress/rest (n=7) or rest/stress (n=23) protocols with technetium-99 m teboroxime (CARDIOTEC, Squibb Diagnostics) in order to assess the clinical usefulness of this new molecule and to compare it to thallium. In all cases coronary artery disease was known or highly suspected, with a history of myocardial infarction in 18 cases (subacute n=6, remote n=12) and/or previous by-pass surgery or PTC A in 5 cases. Medical treatment was not discontinued at the time of stress testing. Coronary angiography was available for 27 patients. Exercise tests for both tracers were carried out on an ergometric bicycle during the same day and the levels of exercise achieved for the thallium studies were very similar to those achieved for teboroxime. Imaging was performed in three planar projections and sudies were evaluated using a model with 4 territories: septal and anterior assumed to correspond to the LAD artery, lateral and latero-posterior (=LCX), inferior and posterior (=RCA) and apex. Classification of results was: normal, ischemic, infarcted and infarcted with ischemia. With reference to the thallium-201 results, agreement was found in 86% (37/43) of normal regions and in 82% (63/77) of abnormal regions. Relative to documented coronary artery lesions (27 patients) sensitivity and specificity of thallium and teboroxime for exact correspondence between arteries and territories were, respectively: thallium, se=71%, sp=64%, teboroxime, se=67%, sp=75%. These results indicate the ability of Cardiotec to evaluate myocardial perfusion with an important time saving since the complete study durations (stress and rest) were: thallium=4h 34 min −22 min and teboroxime=1 h 57 min −41 min.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...