Filter
  • Articles: DFG German National Licenses  (3)
  • Accelerometer  (1)
  • Anthropometry  (1)
  • Bioimpedance  (1)
Source
  • Articles: DFG German National Licenses  (3)
Material
Years
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Intensive care medicine 18 (1992), S. 322-326 
    ISSN: 1432-1238
    Keywords: Body water ; Bioimpedance
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective: To evaluate the relationship between changes in body bioelectrical impedance (BI) at 0.5, 50 and kHz and the changes in body weight, as an index of total body water changes, in acutely ill surgical patients during the rapid infusion of isotonic saline solution.Design: Prospective clinical study.Setting: Multidisciplinary surgical ICU in a university hospital.Patients: Twelve male patients treated for acute surgical illness (multiple trauman=5, major surgeryn=7). Selection criteria: stable cardiovascular parameters, normal cardiac function, signs of hypovolemia (CVP≤5 mmHg, urine ouput 〈1 ml/kg×h).Interventions: After baseline measurements, a 60 min fluid challenge test was performed with normal saline solution, 0.25 ml/kg.Measurements and results: Body weight (platform digital scale), total body impedance (four-surface electrode technique; measurements at 0.5, 50 and 100 kHz) and urine output. Fluid retention induced a progressive decrease in BI at 0.5, 50 and 100 kHz, but the changes were significant for BI 0.5 and BI 100 only, from 40 min after the beginning of the fluid therapy onwards. There was a significant negative correlation between changes in water retention and BI 0.5, with individual correlation coefficients ranging from −0.72 to 0.95 (p〈0.01–0.0001). The slopes of the regression lines indicated that for each kg of water change, there was a mean decrease in BI of 18 ohm, but a substantial inter-individual variability was noted.Conclusion: BI measured at low frequency can represent a valuable index of acute changes in body water in a group of surgical patients but not in a given individual
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of pediatrics 152 (1993), S. 222-225 
    ISSN: 1432-1076
    Keywords: Body composition ; Anthropometry ; Bioelectrical impedance analysis ; Cystic fibrosis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The nutritional status of cystic fibrosis (CF) patients has to be regularly evaluated and alimentary support instituted when indicated. Bio-electrical impedance analysis (BIA) is a recent method for determining body composition. The present study evaluates its use in CF patients without any clinical sign of malnutrition. Thirty-nine patients with CF and 39 healthy subjects aged 6–24 years were studied. Body density and midarm muscle circumference were determined by anthropometry and skinfold measurements. Fat-free mass was calculated taking into account the body density. Muscle mass was obtained from the urinary creatinine excretion rate. The resistance index was calculated by dividing the square of the subject's height by the body impedance. We show that fat-free mass, mid-arm muscle circumference and muscle mass are each linearly correlated to the resistance index and that the regression equations are similar for both CF patients and healthy subjects.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 38 (2000), S. 164-168 
    ISSN: 1741-0444
    Keywords: Human locomotion ; Uphill and downhill walking ; Accelerometer ; Differential barometry ; Differential satellite positioning
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract Activity monitors based on accelerometry are used to predict the speed and energy cost of walking at 0% slope, but not at other inclinations. Parallel measurements of body accelerations and altitude variation were studied to determine whether walking speed prediction could be improved. Fourteen subjects walked twice along a 1.3km circuit with substantial slope variations (−17% to +17%). The parameters recorded were body acceleration using a uni-axial accelerometer, altitude variation using differential barometry, and walking speed using satellite positioning (DGPS). Linear regressions were calculated between acceleration and walking speed, and between acceleration/altitude and walking speed. These predictive models, calculated using the data from the first circuit run, were used to predict speed during the second circuit. Finally the predicted velocity was compared with the measured one. The result was that acceleration alone failed to predict speed (meanr=0.4). Adding altitude variation improved the prediction (meanr=0.7). With regard to the altitude/acceleration-speed relationship, substantial inter-individual variation was found. It is concluded that accelerometry, combined with altitude measurement, can assess position variations of humans provided inter-individual variation is taken into account. It is also confirmed that DGPS can be used for outdoor walking speed measurements, opening up new perspectives in the field of biomechanics.