Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles: DFG German National Licenses  (2)
  • Ancurysmal bone cyst  (1)
  • Array Systems  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Skeletal radiology 18 (1989), S. 109-113 
    ISSN: 1432-2161
    Keywords: Ancurysmal bone cyst ; Bone tumor ; Sacrum
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A series of five cases of sacral aneurysmal bone cyst is presented. There were three females and two males, the youngest patient being 11 years old, the oldest 41 years old. All patients had pain of long duration with varying signs of nerve root compression. Three patients had micturitional problems. Four patients had a palpable mass which was tender. All had standard radiographs. Tomograms, computed tomography (CT) scans or MRI (magnetic resonance imaging) were obtained in some patients. In all patients a definite histologic diagnosis was established. Four lesions healed after resection (two cases) or curettage (two cases). One patient is considered to have a stable lesion which is not progressing.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Experimental astronomy 9 (1999), S. 17-38 
    ISSN: 1572-9508
    Keywords: Radio Astronomy ; Array Systems ; Acousto-Optical Spectrometer ; Back-ends ; Radiometers ; Heterodyne Instrumentation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract In this paper an array acousto-optical spectrometer (AOS) with four 1 GHz bands and a frequency channel spacing of 1 MHz is presented. A discussion about the requirements which have to be fulfilled by the presented instrument for applications in radio astronomy is given as well as e detailed description of the optical design. Remarkable test results have been achieved such as an Allan-Variance minimum time of about 1000 s, identical noise performance, and identical frequency calibration of all bands. The reproducibility of measurements has been demonstrated by tests with CH3CN, using an absorption cell. The question of the maximum number of bands per array AOS is discussed. Although it may seem promising to increase the number of bands per optical unit to e.g. eight or more instead of four, a strong limitation has been found due to the increasing r.f. power level on the Bragg cell which affects the baselines of the spectra.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...