Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Artikel: DFG Deutsche Nationallizenzen  (4)
  • Chemistry  (3)
  • Ethylene oxide  (1)
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Journal of industrial microbiology and biotechnology 12 (1993), S. 399-402 
    ISSN: 1476-5535
    Schlagwort(e): Biological indicators ; Ethylene oxide ; Medical devices ; International standards
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
    Notizen: Summary Biological indicators (BIs) are used to monitor ethylene oxide (EO) gas sterilization processes for medical devices. Several European and United States BIs for EO sterilization were evaluated for resistance according to both United States Pharmacopeia (USP) XXI and United Kingdom's (UK) tests for D-values. US BIs areB. subtilis var. niger spores on paper strips or disc carriers while European BIs use aluminum strips, quartz sand, or cotton yarn. Numerous BIs per run and runs per lot, as well as 2–3 different lots of BIs from each manufacturer, were examined. Both British and US BIs met their respective label claims for rates of inactivation when tested against British and USP EO test parameters, respectively. However, Danish BIs, on cotton yarn or quartz sand, were not inactivated following USP specifications during the exposure dwell times tested (600 mg L−1 EO, 54°C, 60% RH, 0–110 min). The Danish BIs will require further testing in order for us to determine if theirB. subtilis spores are unusually resistant to EO or if the spore carrier substrates protect the spores from the sterilizing gas. In conclusion, the British and American BIs for EO sterilization are equivalent in resistance despite differences in carrier substrate, recovery conditions, calculation methods for D-values, and the labeled sterilization conditions for use.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 0021-9304
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Medizin , Technik allgemein
    Notizen: The induction of tumor necrosis factor α (TNF-α) by polytetrafluoroethylene (PTFE) particles (5-50 μm) and by bacterial lipopolysaccharide (LPS) and lipoteichoic acid (LTA) was examined in RAW cell cultures. Twenty-four-hour culture supernatants from the treated and control cells were assayed for TNF-α using a mouse L929 cell cytotoxicity assay. Untreated RAW cells produced low levels of endogenous TNF-α in the culture supernatants. Addition of 0.5 ng to 1 μg/ml LPS or 1 ng to 1 μg/ml LTA increased the TNF-α production by 7-3570-fold and 2-815-fold, respectively. Addition of 1-5 mg PTFE increased the TNF-α production by 6-17-fold over the untreated control cell levels. The cells exposed to PTFE and 0.5 ng/ml LPS or 5 ng/ml LTA produced TNF-α levels that were significantly higher than those produced by any inducer alone. Thus, both LTA, a Gram-positive bacterial cell wall component and LPS, a Gram-negative bacterial cell wall component, can induce TNF-α production, which is further enhanced by PTFE particles in RAW cells. © 1996 John Wiley & Sons, Inc.
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    ISSN: 0049-8246
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Physik
    Notizen: It was demonstrated that a total reflection x-ray fluorescence spectrometer, using monoenergetic synchrotron radiation as the primary x-ray source, is suitable to measure the concentration of transmutational elements in Cu and Fe metal matrices. In a typical irradiation of copper with 590 MeV protons or with spallation neutrons, where the damage dose is 0.4 dpa (displacement per atom), the calculated concentration of transmutational elements is Ni 25, Co 8 and Fe 8 μg g-1. The results show that the minimum detectable concentrations were lower than these values. The energy of the sychrotron radiation was set just below the K-edge energy of the matrix element, eliminating the large peak due to the matrix. As an example, in the case of a Cu (Z = 29) matrix, the minimum detectable concentration for Ni (Z = 28) was as low as 3 μg g-1. In order to check systematically the possible geometric arrangements of beam direction-reflector position-detector position, a new vacuum chamber was designed and tested. It provides all technical components for remote control of the adjustment procedure to align the reflector in total reflection geometry. Two ways of positioning the reflector in the beam, vertical to the plane of polarization and parallel to that plane, were investigated, to find the best excitation conditions and lowest limits of detection. A few pg corresponding to a concentration of ng g-1 of samples where the matrix can be easily removed as in aqueous or acidic solutions and 50 ng g-1 concentration of metals in a light matrix as in oil were found as detection limits.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    ISSN: 0049-8246
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Physik
    Notizen: High-purity copper samples were irradiated with high-energy protons and neutrons. The concentration of transmutational elements was measured by means of the total reflection x-ray fluorescence method using synchrotron radiation. The spectra of non-irradiated samples were substracted from the spectra of the irradiated samples. By this evaluation method, the minimum detectable concentration was as low as 1.5 μg g-1 in a copper matrix.
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...