    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: A time-of-flight mass spectrometer has been developed using a reflectron in which the voltages placed on the lens elements correspond to a function describing the arc of a circle. This curved-field reflectron enables acquisition of focused product-ion mass spectra at a single reflectron voltage. In this paper, we present results from this instrument for the amino acid sequencing of several peptides and describe the method of mass calibration.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 8 (1994), S. 781-785 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The ability to simultaneously focus a wide mass range of metastable fragment ions formed after the initial ionization event in a matrix-assisted laser desorption/ionization time-of-flight mass spectrometer has been made possible by the development of a new type of ion reflector. This coaxially designed time-of-flight instrument employs a modified single stage reflector whose axial voltage gradient rises differentially in order to produce an alignment of energy focal points for product ions. In contrast, product-ion focusing in conventional constant field reflectors occurs over a broad range of distances from the reflectron exit. Approximately 90% of the product-ion mass spectrum can be collected without adjustment, thereby eliminating the need to scan the reflector voltage. Design considerations of the curved field reflectron, its calibration properties and representative metastable spectra of several peptides are discussed.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 7 (1993), S. 1037-1040 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: A new type of curved-field reflectron has been developed for the energy focusing of ions formed after initial acceleration in time-of-flight (TOF) mass spectrometers. These include ions generated in the dissociation region of a tandem TOF, as well as metastable decay products formed in the field-free drift region prior to their reflection. Unlike conventional linear-field reflectrons, which focus product ions to different focal lengths that are proportional to the mass (energy) of the fragment, the new curved-field reflectron energy focuses all ions to within a small region near the exit of the reflectron. Thus, the collection of resolved fragment peaks is possible without scanning or stepping the potential gradient of the reflectron, enabling faster acquisition of the production spectrum and, more importantly, true multiplex recording of the spectra from each ionization event. Theoretical considerations of the design are discussed along with an evaluation of collision-induced dissociation data, demonstrating the performance of the new reflectron in a tandem TOF instrument.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 6 (1992), S. 753-757 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: An ion-trap detector has been modified for matrix-assisted laser desorption/ionization using a pulsed frequency-quadrupled Nd: YAG laser and extended mass range up to 3300 u using the resonant-rejection mode of operation. The matric-assisted laser desorption/ionization mass spectra of a number of peptides are reported, and the effects due to the synchronization of the laser pulses and the phase of the RF voltage applied to the ring electrode are described.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 28 (1993), S. 1129-1134 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A tandem time-of-flight mass spectrometer was developed to be used for the study of collision-induced dissociation (CID) products of peptides and small proteins. The instrument incorporates two single-stage reflectrons, the first to energy focus the precursor ions to be fragmented and the second to both energy focus and disperse the product ions formed in the collision cell. Single-stage rather than two-stage reflectrons were used because the overall transmission is higher, interferences with grid wire fields are minimized and the mass calibration of product ion spectra is exactly linear with time. The CID product ion spectra of rhodamine and several peptides were acquired and found to exhibit very similar fragmentation patterns to those acquired in the B/E linked scan mode of a magnetic sector mass spectrometer.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...