Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Artikel: DFG Deutsche Nationallizenzen  (2)
  • Cholesterol  (1)
  • Electromyogram amplitude  (1)
Datenquelle
  • Artikel: DFG Deutsche Nationallizenzen  (2)
Materialart
Erscheinungszeitraum
  • 1
    Digitale Medien
    Digitale Medien
    Amsterdam : Elsevier
    Chemistry and Physics of Lipids 73 (1994), S. 3-25 
    ISSN: 0009-3084
    Schlagwort(e): Cholesterol ; Drugs ; Dynamic heterogeneity ; Lipid domains ; Local order ; Phase transition ; Phase-separation dynamics ; Phospholipids
    Quelle: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Thema: Biologie , Chemie und Pharmazie , Physik
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    European journal of applied physiology 63 (1991), S. 345-348 
    ISSN: 1439-6327
    Schlagwort(e): Electromyogram amplitude ; Mean power frequency ; Dynamic exercise ; Temperature ; Soleus muscle
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Summary Differing results have been reported concerning the direction and quantity of the electromyogram (EMG) amplitude response to changes in tissue temperature. The EMG signals from the soleus muscle of six healthy human subjects were therefore recorded during dynamic exercise (concentric contractions) at ambient temperatures of 30°C and 14°C. The mean skin temperature $$(\bar T_{sk} )$$ above the muscle investigated was 32.9° C and 21.7° C, respectively. The core temperature, estimated by rectal temperature, was unchanged. The cooling of the superficial tissues caused approximately a doubling of the EMG amplitude. For the probability level 0.9 in the amplitude probability distribution function, the average signal level increased from 73 μV to 135 μV (P=0.02). The average mean power frequency of the EMG signal was reduced from 142 Hz to 83 Hz (P=0.004). The amplitude increase was not due to shivering but other possible explanations are presented. As the changes in T sk investigated were within the range which may occur normally during the working hours, it was concluded that T sk should be carefully controlled in vocational EMG studies.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...