Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles: DFG German National Licenses  (3)
  • Cyclodextrin polymer  (2)
  • Column-coupling system  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 18 (1995), S. 348-352 
    ISSN: 0935-6304
    Keywords: Capillary electrophoresis ; Enantiomers ; Cyclodextrin polymer ; Organic modifiers ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Enantiomeric separation of some basic compounds, namely selegiline, amphetamine, and clenbuterol, was studied by capillary electrophoresis using an uncharged β-cyclodextrin polymer added to the background electrolyte at pH 2.5. Both complexation and resolution were influenced by the concentration of the chiral polymer confirming our previous results obtained in our earlier work for a wide number of pharmaceutical compounds. In this further study, we examined the influence of different organic additives to the background electrolyte on the enantioselectivity of the chiral selector, also using an extended number of analytes. In most cases, the use of an organic additive resulted in a decrease of resolution. However opposite to that, in some cases, e.g. ephedrine, the organic solvent proved to be essential to achieve enantiomeric resolution. Furthermore the influence of the capillary temperature on the resolution of the analytes was evaluated. Increase of temperature had a deleterious effect on the resolution of the enantiomers. For ephedrine, however, relatively high temperature (50 °C) proved to be advantageous, for the resolution of the optical isomers.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0173-0835
    Keywords: Capillary zone electrophoresis ; Chiral separations ; Column-coupling system ; α-Hydroxycarboxylic acids ; Sensitivity of optical detection ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: A new approach is described for highly sensitive chiral analyses by capillary zone electrophoresis, based on using an on-line combination of two capillaries filled with either chiral selective or achiral background electrolytes (BGE). Thus, the BGEs are selected in such a way that the first capillary provides optimum chiral selectivity and the second one optimum detection sensitivity. Direct chiral separations of enantiomers of mandelic, m-methoxymandelic, 3-phenyllactic and 3-indolelactic acids served as a model example for testing the approach proposed. The analyses were performed in a BGE containing acetate as a coion and L-OH-proline or aspartame as a chiral selector. For high sensitive analyses, an arrangement containing on-line combined chiral and achiral media were tested in one or two capillaries coupled via a bifurcation block. A detection limit as low as 10-18 moles was reached in the column-coupling system when the direct chiral separation was performed in the first capillary, filled with 20 mM acetate buffer, pH 4.4, containing 8 mM Cu (II) and 16 mM aspartame (L-aspartyl-L-phenylalanine methylester) and separated enantiomers were detected in the second capillary, filled with 20 mM acetate buffer, pH 3.1. The principle described is of general use in cases where the separation and detection of analytes in question require mutually different BGEs to reach the optimum selectivity and sensitivity, respectively.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0173-0835
    Keywords: Enantiomers ; Capillary electrophoresis ; Cyclodextrin polymer ; α-Hydroxy acids ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Uncharged β-cyclodextrin polymer was used as chiral selector for the enantiomeric separation of some α-hydroxy acids by capillary electrophoresis. Complexation and enantiomeric resolution of mandelic acid, m-hydroxy and p-hydroxymandelic acid, 3,4-dihydroxymandelic acid, as well as 2- and 3-phenyllactic acid were studied, changing the concentration of the β-cyclodextrin polymer added to the background electrolyte at different pH in the range of 4.5-7. Furthermore, the effects of the concentration of the background electrolyte, column temperature, and applied voltage on chiral resolution were also examined. The best enantiomeric separations were obtained using a background electrolyte at pH 6 containing 100 mg/mL of β-cyclodextrin polymer.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...