Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles: DFG German National Licenses  (4)
  • Engineering  (3)
  • Sarin  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Archives of toxicology 74 (2000), S. 165-172 
    ISSN: 1432-0738
    Keywords: Key words Organophosphorus compounds ; Cholinesterase inhibitors ; Soman ; Sarin ; Tabun ; GF ; VX ; Convulsions ; Seizures ; EEG activity ; Anticonvulsants ; Atropine ; Biperiden ; Anticholinergic compounds
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The ability of the nerve agents tabun, sarin, soman, GF, VR, and VX to produce brain seizures and the effectiveness of the anticholinergics biperiden HCl or atropine SO4 as an anticonvulsant treatment were studied in a guinea-pig model. All animals were implanted a week prior to the experiment with cortical electrodes for electroencephalogram (EEG) recordings. On the day of exposure, the animals were pretreated with pyridostigmine (0.026 mg/kg, i.m.) 30 min prior to challenge with a 2 × LD50 dose (s.c.) of a given agent. In separate experiments, animals were challenged with 5 × LD50 (sc) of soman. One minute after agent challenge, the animals were treated intramuscularly (i.m.) with 2 mg/kg atropine SO4 admixed with 25 mg/kg 2-PAM Cl and then observed for the onset of seizure activity. Five minutes after the start of nerve agent-induced EEG seizures, animals were treated i.m. with different doses of biperiden HCl or atropine SO4 and observed for seizure termination. The anticonvulsant ED50 of biperiden HCl and atropine SO4 for termination of seizures induced by each nerve agent was calculated and compared. With equally toxic doses (2 × LD50) of these agents, continuous EEG seizures (status epilepticus) developed in all animals challenged with soman, tabun, or VR, and in more than 90% of the animals challenged with GF or sarin. In contrast, only 50% of the animals developed seizures when challenged with VX. The times to onset of seizures for soman, tabun, GF, and sarin were very similar (5–8 min) while for VR, it was about 10 min. In the case of VX, not only was the time to seizure development longer (20.7 min), but the seizure activity in 19% of the animals terminated spontaneously within 5 min after onset and did not return. Under these conditions, the anticonvulsant ED50s of biperiden HCl for soman, GF, VR, tabun, sarin, and VX were 0.57, 0.51, 0.41, 0.2, 0.1, and 0.09 mg/kg, respectively, while those of atropine SO4 for soman, VR, tabun, GF, sarin, and VX were 12.2, 11.9, 10.4, 10.3, 5.1, and 4.1 mg/kg, respectively. In separate experiments, the anticonvulsant ED50 doses of biperiden for animals challenged with 2 or 5 × LD50 of soman were 0.48 (95% confidence limits 0.25–0.73) or 0.57 (95% CI 0.38–0.84) mg/kg, respectively, while the anticonvulsant ED50s for atropine (12.2 mg/kg, i.m.) were identical under these same two challenge conditions. The present study demonstrates that all nerve agents can produce status epilepticus and that the therapeutic effectiveness of atropine and biperiden roughly paralleled the seizurogenic potential of these agents.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 21 (1985), S. 1027-1037 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: This analysis presents a procedure that can reliably debug computer programs. The central idea lies in creating a fictitious problem whose exact solution exists and is known, and in obtaining the numerical solution for comparison with the exact solution. If the two solutions are found identical, it is safe to assume that the computer program computing the fictitious problem is free of bugs. Then, conversion of the program computing the ficititious problem to that computing the real problem generally involves changing only one single statement. This procedure may be jointly used with all the existing numerical schemes.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    International Journal for Numerical Methods in Fluids 12 (1991), S. 965-983 
    ISSN: 0271-2091
    Keywords: Navier-Stokes ; Incompressible ; Convergence ; Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: An algorithm, called the Algebraic Continuity Equations Solver (ACES), is developed based on the concept that two algebraic equations (three for 3D problems) can be generated from rearranging the discretized continuity equations. These rearranged equations are used to re-compute the two velocity components (three for 3D problems), whose values are already obtained from solving the momentum equations. When written in a Navier-Stokes computer code, this algorithm is equivalent to a fairly concise set of statements and can be implemented immediately after the computation of the continuity equation. In our analysis, ACES is used in conjunction with a grid having nodal velocity components at the vertices and the nodal pressure at the centre of each computational cell.With the aid of ACES, correction of velocity components during the iteration can be inexpensively made, leading to faster convergence rates or rendering otherwise divergent computations convergent.Test problems include benchmark problems such as lid-driven cavity flows and buoyancy-driven cavity flows of various parametric values and grid sizes. A 3D time-dependent flow in an irregular geometry is also investigated. Discussions are presented to clarify some relevant issues. A possible reason why we think ACES is capable of improving the convergence rates is also given.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    International Journal for Numerical Methods in Fluids 9 (1989), S. 193-212 
    ISSN: 0271-2091
    Keywords: Navier-Stokes ; Staggered grid ; Primitive variable formulation ; Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Nine finite difference schemes using primitive variables on various grid arrangements were systematically tested on a benchmark problem of two-dimensional incompressible Navier-Stokes flows. The chosen problem is similar to the classical lid-driven cavity flow, but has a known exact solution. Also, it offers the reader an opportunity to thoroughly evaluate accuracies of various conceptual grid arrangements.Compared to the exact solution, the non-staggered grid scheme with higher-order accuracy was found to yield an accuracy significantly better than others. In terms of ‘overall performance’, the so-called 4/1 staggered grid scheme proved to be the best. The simplicity of this scheme is the primary benefit. Furthermore, the scheme can be changed into a non-staggered grid if the pressure is replaced by the pressure gradient as a field variable.Finally, the conventional staggered grid scheme developed by Harlow and Welch also yields relatively high accuracy and demonstrates satisfactory overall performance.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...