Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles: DFG German National Licenses  (11)
  • Polymer and Materials Science  (9)
  • Food Science, Agricultural, Medicinal and Pharmaceutical Chemistry  (2)
Source
  • Articles: DFG German National Licenses  (11)
Material
Years
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 29 (1998), S. 609-617 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Microstructural, mechanical and corrosive properties of friction stir welded aluminium jointsFriction stir welding (FSW) is a novel solid state welding process. It allows joining of high strength aluminum alloys, generally considered as difficult-to-weld with conventional technologies, without loss in joint strength. Results of investigations on selfmade FSW butt joints of the aluminum alloys 2024-T3 and 6013-T4 are presented. First, the microstructure of the weld seam and heat affected zone is characterised metallographically and by hardness measurements. By tensile, fatigue endurance (SN) and fatigue crack propagation tests it is demonstrated, that especially the FSW-joints of 2024-T3 sustain high mechanical loadings. Investigations on the corrosion properties reveal a certain sensitivity of the 2024-T3 joints to intergranular and exfoliation corrosion.
    Notes: Das Reibrührschweißen (friction stir welding FSW) ist ein neues Fügeverfahren, mit dem auch die schwer schmelzschweißbaren, höherfesten Aluminiumlegierungen ohne große Festigkeitsverluste verschweißt werden können. Erste Ergebnisse von Untersuchungen an selbst hergestellten FSW-Stumpfnähten der Aluminiumlegierungen 2024-T3 und 6013-T4 werden vorgestellt. Zunächst wird das Gefüge der Naht und der Wärmeeinflußzone mikrostrukturell und durch Härteverläufe charakterisiert. Weiterhin wird mit Zug-, Schwingfestigkeits- und Rißfortschrittsversuchen nachgewiesen, daß insbesondere die FSW-Nähte der Legierung 2024-T3 außerordentlich hohe mechanische Belastungen ertragen. Abschließende Korrosionsuntersuchungen der FSW-Nähte zeigen eine gewisse Anfälligkeit der abschreckempfindlichen Legierung 2024-T3 für interkristalline Korrosion und Schichtkorrosion.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0947-5117
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim [u.a.] : Wiley-Blackwell
    Materials and Corrosion/Werkstoffe und Korrosion 41 (1990), S. 547-555 
    ISSN: 0947-5117
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Stress corrosion cracking tests on the aluminium-lithium alloy 2091The stress corrosion cracking (SCC) behaviour of an early material (CP274) of the Al-Li-Cu-Mg-Zr alloy 2091 was investigated. With a 39 mm thick plate in the T851 aging condition constant-strain and constant-load tests were conducted in the short transverse direction. Alternately immersed in 3,5% NaCl solution this material is found to be highly susceptible to SCC. A threshold stress below 50 MPa is measured. Using crack initiation as failure criterion the time to failure data obtained from C-ring specimens are comparable with those of uniaxial tension specimens which are considered as failed if fracture is observed. Performing constant-load tests under continuous immersion the determined SCC resistance depends upon the used corrosive environment. In 3.5% NaCl solution no SCC failure is observed whereas in an aqueous solution of 2% NaCl + 0.5% Na2CrO4 at pH = 3 a threshold stress below 100 MPa is found.Furthermore the SCC behaviour of a 1.6 mm thick sheet in two underaged heat treatments was investigated in the rolling direction. Aged 12 h at 135°C the material is very susceptible to SCC as revealed by alternate immersion tests in 3.5% NaCl solution. The SCC resistance determined using the same accelerated test is improved by aging 100 h at 150°C. SCC tests under continuous immersion in 3.5% NaCl solution indicate no SCC susceptibility if the specimens are loaded in the elastic region. Using the slow strain rate technique the alloy in both heat treatments is not susceptible to SCC if the specimens are exposed in 3.5% NaCl solution. However, slow strain rate tests in the chromate inhibited electrolyte predict a SCC susceptibility. For the alloy 2091-12 h/135°C the fracture energy which is used as parameter to indicate SCC susceptibility reveals a pronounced reduction with decreasing strain rate in the latter electrolyte compared with the values in inert environment. For the longer aged material a smaller diminution of the fracture energy is measured.
    Notes: Es wurde das Spannungsrißkorrosionsverhalten einer vorläufigen Variante (CP274) der Al-Li-Cu-Mg-Zr-Legierung 2091 untersucht. Eine 39 mm dicke Platte im warmausgelagerten Zustand T851 wurde in kurzer Querrichtung geprüft unter konstanter Verformung und konstanter Belastung. Bei alternierendem Eintauchen in wäßrige 3,5%ige NaCl Lösung erweist sich der Werkstoff als sehr anfällig für Spannungsrißkorrosion (SpRK). Die kritische Grenzspannung für Spannungsrißkorrosion liegt unter 50 MPa. Wird als Merkmal des Versagens bei C-Ring-Proben der erste Anriß und bei einachsigen Zugproben der Bruch gewählt, so ergeben diese Proben trotz unterschiedlicher Belastungsart über-einstimmende Standzeiten. Bei der Prüfung unter konstanter Belastung, bei der die Proben ständig in die korrosive Lösung eingetaucht sind, hängen die Standzeiten vom benutzten Elektrolyten ab. In 3,5%iger NaCl-Lösung zeigt der Werkstoff einen hohen SpRK-Widerstand, während in einer sauren, wäßrigen Lösung von 2% NaCl + 0,5% Na2CrO4 bei pH = 3 eine kritische Grenzspannung unter 100 MPa gefunden wird.Desweiteren wurde in Walzrichtung ein 1.6 mm dickes Blech untersucht in zwei unteralterten Zuständen: 12 h/135°C und 100 h/150°C. Die Prüfung mittels Biegeproben bei alternierendem Eintauchen in 3,5%ige NaCl-Lösung ergibt eine hohe SpRK-Empfindlichkeit des Bleches im Wärmebehandlungszustand 12 h/135°C. Mit zunehmender Warmauslagerung verbessert sich der SpRK-Widerstand. Bei ständigem Eintauchen in 3,5%ige NaCl-Lösung zeigt der Werkstoff bei Belastungen unterhalb der Streckgrenze keine SpRK-Anfälligkeit. Die Vorhersagen der Prüfung mit langsamer Dehnrate hinsichtlich des SpRK-Verhaltens hängen vom benutzten Elektrolyten ab. Während in 3,5%iger NaCl-Lösung keine Anzeichen für Spannungsrißkorrosion beobachtet werden, wird in der chromatinhibierten 2%igen NaCl-Lösung für beide Wärmebehandlungszustände eine SpRK-Empfindlichkeit gefunden. Der Abfall der Bruchenergie in Abhängigkeit der Dehnrate, der als Maß für die SpRK-Anfälligkeit dient, ist für die Wärmebehandlung 12 h/135°C besonders ausgeprägt. Der verbesserte SpRK-Widerstand des Bleches in dem warmausgelagerten Zustand 100 h/150°C wird durch einen weniger ausgeprägten Abfall der Bruchenergie wiedergegeben.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim [u.a.] : Wiley-Blackwell
    Materials and Corrosion/Werkstoffe und Korrosion 43 (1992), S. 106-114 
    ISSN: 0947-5117
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: On the stress corrosion cracking behaviour of recrystallized 8090-T81 SheetsThe stress corrosion cracking behaviour of a recrystallized sheet of the Al-Li-Cu-Mg-Zr alloy 8090-T81 was studied performing accelerated tests under constant deformation, constant load, and slow strain rate conditions. The used electrolytes were an aqueous 3.5% NaCl solution, an aqueous solution of 2% NaCl + 0.5% Na2CrO4 at pH = 3, and synthetic seawater according to ASTM D1141. Alternately immersed in 3.5% NaCl solution according to ASTM G44 the investigated alloy was found to be susceptible to stress corrosion cracking was not promoted by continuous immersion in aerated 3.5% NaCl solution, 3.5% NaCl solution saturated with carbon dioxide, and in acid chromate inhibited 2% NaCl solution. Using the slow strain rate technique with continuously immersed flat tensile specimens stress corrosion cracking was only observed in synthetic seawater. Under specific environmental conditions hydrogen embrittlement can occur in the investigated material.
    Notes: Das Spannungsrißkorrosionsverhalten eines rekristallisierten Bleches der AlLiCuMgZr-Legierung 8090-T81 wurde mit beschleunigten Prüfverfahren unter konstanter Verformung, konstanter Belastung und mit langsamer Dehnrate untersucht. Als Elektrolyte wurden eine wäßrige 3,5%ige NaCl-Lösung, eine wäßrige Lösung von 2% NaCl + 0,5% Na2CrO4 bei pH = 3 und künstliches Meerwasser nach ASTM D1141 benutzt. Im Wechseltauchversuch in 3,5%iger NaCl-Lösung (entsprechend ASTM G44) erweist sich das in Walzrichtung untersuchte Blech als anfällig für Spannungsrißkorrosion. Im Dauertauchversuch in belüfteter oder mit Kohlendioxid gesättigter 3,5%iger NaCl-Lösung sowie in saurer, chromathaltiger 2%iger NaCl-Lösung (nach LN 65666) zeigt der Werkstoff dagegen hohen Spannungsrißkorrosionswiderstand. Bei der Prüfung mit langsamer Dehnrate, bei der die Zugproben kontinuierlich in den Elektrolyten eingetaucht sind, wird nur in künstlichem Meerwasser eine Spannungsrißkorrosionsanfälligkeit beobachtet. Es gibt Hinweise, daß Wasserstoff unter bestimmten Umgebungsbedingungen den untersuchten Werkstoff versprödet.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim [u.a.] : Wiley-Blackwell
    Materials and Corrosion/Werkstoffe und Korrosion 45 (1994), S. 369-377 
    ISSN: 0947-5117
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Untersuchung des SpRK-Verhaltens von Platten hochfester Aluminiumlegierungen mittels Prüfung mit langsamer Dehnrate in einer wäßrigen Lösung von 3% NaCl + 0,3% H2O2Das Spannungsrißkorrosionsverhalten von Plattenmaterial verschiedener Aluminiumlegierungen wurde in kurzer Querrichtung mittels der Prüfung mit langsamer Dehnrate untersucht. Als korrosive Umgebung wurde eine wäßrige Lösung von 3% NaCl + 0,3% H2O2 benutzt. Wechseltauchversuche nach ASTM G44 unter konstanter Verformung wurden zu Vergleichszwecken ebenfalls durchgeführt. In beiden Prüfverfahren erweisen sich die Legierungen 2024-T351, 2091-T8X51, 7050-T651 und 7475-T651 als sehr anfällig für Spannungsrißkorrosion. Für die Legierung 8090-T8171 wird im Wechseltauchversuch ein geringer Spannungsrißkorrosionswiderstand gefunden, während die Prüfung mit langsamer Dehnrate ein besseres Verhalten anzeigt. Die Prüfung mit langsamer Dehnrate versagt bei den weniger empfindlichen Legierungen 2024-T851 und 7050-T7651. Die bei diesen Werkstoffen beobachtete Abnahme der Bruchenergie wird, ebenso wie bei den beständigen Legierungen: 7050-T7351 und 7475-T7351, durch Lochfraß und interkristalline Korrosion verursacht, wie durch Vorkorrosionsversuche nachgewiesen wurde. Die Prüfung mit langsamer Dehnrate in einer wäßrigen Lösung von 3% NaCl + 0,3% H2O2 eignet sich als ein schnelles Prüfverfahren, um bei Aluminiumhalbzeug hohe. Anfälligkeiten für Spannungsrißkorrosion nachzuweisen. Da durch den Zusatz von Wasserstoffperoxid auch andere Korrosionsarten gefördert werden, sind Vorkorrosionsuntersuchungen unbedingt erforderlich.
    Notes: The stress corrosion cracking (SCC) behaviour of aluminium alloy plate materials was investigated in the short transverse direction using the slow strain rate (SSR) testing technique. The synthetic environment used was an aqueous solution of 3% NaCl + 0.3% H2O2. Reference tests under constant deformation and alternate immersion conditions according to ASTM G44 were performed, too. Both static and dynamic loading tests indicate high SCC susceptibility with the alloys 2024-T351, 2091-T8X51, 7050 T651 and 7475-T651. For the alloy 8090-T8171, a low SCC resistance is found in the alternate immersion tests, whereas a rather moderate sensitivity is observed performing SSR tests. The SSR testing technique fails to indicate the SCC sensitivity of the more resistant alloys 2024-T851 and 7050-T7651. As demonstrated by pre-exposure tests, the reduction of fracture energy observed with the latter alloys as well as with the immune alloys 7050-T7351 and 7475-T7351 is caused by pitting and intergranular corrosion. Using an aqueous solution of 3% NaCl + 0.3% H2O2, the SSR testing technique is a useful rapid method to screen wrought aluminium alloys which are quite sensitive to environmentally assisted cracking. Because chloride-peroxide solutions are also conducive to corrosion processes independent of stress, pre exposure tests are required to be incorporated into such sorting tests.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 18 (1987), S. 258-265 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Corrosion Behaviour of the Al-Li-Cu-Mg AlloyThe localized corrosion behaviour of the Al-Li-Cu-Mg alloy 8090-T651 (25 mm thick plate) was investigated using salt spray tests, EXCO tests and tests according to the MIL-H-6088F specification. These accelerated laboratory tests indicate that the material is susceptible to intergranular and exfoliation corrosion. The stress corrosion cracking behaviour was studied under constant load, constant deformation and slow strain rate conditions. The material was found to be resistant against stress corrosion cracking in the long transverse direction. In the short transverse direction a threshold stress below 50 MPa was determined. The same values were measured for the conventional alloys 2014-T351 and 2024-T351. The fracture surfaces of specimens failed due to stress corrosion cracking were examined using a scanning electron microscope. Fractographic features attributed to corrosion were discussed.
    Notes: Eine 25 mm dicke Platte der Al-Li-Cu-Mg Legierung 8090-T651 wurde auf ihre Anfälligkeit gegen Lochfraß, interkristalline Korrosion und Schichtkorrosion hin untersucht. Die lokalen Korrosionseigenschaften wurden mittels genormter Verfahren geprüft; verschiedene Salzsprühnebelprüfungen, die Prüfung nach der Spezifikation MIL-H-6088F und der EXCO Test wurden angewandt. In diesen beschleunigten Prüfverfahren zeigt der Werkstoff eine deutliche Anfälligkeit gegen interkristalline Korrosion und Schichtkorrosion. Das Spannungsrißkorrosionsverhalten wurde unter konstanter Last, konstanter Dehnung und mit langsamer Dehnrate geprüft. In der langen Querrichtung ist der Werkstoff nicht anfällig gegen Spannungsrißkorrosion. In der kurzen Querrichtung liegt die kritische Grenzspannung für Spannungsrißkorrosion unterhalb von 50 Mpa. Vergleichsprüfungen der konventionellen Legierungen 2014-T351 und 2024-T351 führten zu gleichen Ergebnissen. Die durch Spannungsrißkorrosion bedingten Bruchflächen wurden im Rasterelektronenmikroskop auf korrosionsspezifische Merkmale hin untersucht.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim [u.a.] : Wiley-Blackwell
    Materials and Corrosion/Werkstoffe und Korrosion 40 (1989), S. 661-668 
    ISSN: 0947-5117
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Korrosionsverhalten der Legierung 8090-T6Es wurde das Schicht- und Spannungsrißkorrosionsverhalten eines nicht rekristallisierten Bleches der Al-Li-Cu-Mg-Zr-Legierung 8090-T6 untersucht. Nach 96 h Prüfdauer in der EXCO-Lösung zeigte dieser Werkstoff eine hohe Anfälligkeit gegen Schichtkorrosion. Die Prüfung in der Salznebelkammer bei unterbrochener Sprühdauer (MASTMAASIS Test) ergab ein besseres Verhalten. Der Schichtkorrosionsangriff war geringfügig. Das Spannungsrißkorrosionsverhalten wurde unter konstanter Last, konstanter Verformung und mit langsamer Dehnrate in 3,5% NaCl Lösung geprüft. Zusätzlich wurde bei der Prüfung unter konstanter Last auch der in der Luftfahrtnorm LN 65666 beschriebene Elektrolyt verwendet. Der Werkstoff erwies sich in Walzrichtung als beständig gegen Spannungsrißkorrosion. Bei der Prüfung mit langsamer Dehnrate streuten die Werte der relativen Bruchenergie im Bereich der niedrigen Dehnraten. Dies wird zurückgeführt auf Lochfraß, der im Zugversuch als Rißkeim wirkt und die Duktilität der Zugproben herabsetzt.
    Notes: The exfoliation corrosion and stress corrosion cracking behaviour of an unrecrystallized sheet of the Al-Li-Cu-Mg-Zr alloy 8090-T6 was investigated. The material was highly susceptible to exfoliation corrosion in the 96 h EXCO test, whereas the intermittent salt spray test (MASTMAASIS test) revealed only a slight degree of exfoliation. The stress corrosion cracking behaviour was investigated in 3.5% NaCl solution under constant load, constant deformation, and slow strain rate conditions. Tests under constant load were also performed in an inhibited and acidified 2% NaCl solution according to the German standard LN 65666. In these accelerated tests the investigated alloy was found to be not susceptible to stress corrosion cracking in the rolling direction. The slow strain rate tests revealed a great scattering of the relative fracture energy with decreasing strain rates. This scatter is probably caused by pits acting as crack nuclei thus giving rise to scatter of the ductility.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim [u.a.] : Wiley-Blackwell
    Materials and Corrosion/Werkstoffe und Korrosion 45 (1994), S. 255-263 
    ISSN: 0947-5117
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Zum SpRK-Verhalten von Blechen aus Aluminiumlegierungen in einer wäßrigen Lösung von 3% NaCl + 0,3% H2O2Das Spannungsrißkorrosionsverhalten von Blechmaterial verschiedener Aluminiumlegierungen wurde in langer Querrichtung mittels der Prüfung mit, langsamer Dehnrate untersucht. Als korrosive Umgebung wurde eine wäßrige Lösung von 3% NaCl + 0,3% H2O2 benutzt. Die Prüfung mit langsamer Dehnrate liefert für die Legierungen 2024-T351, 8090-T81 und 2091 CPHK T8X keinen Hinweis auf eine Spannungsrißkorrosionsempfindlichkeit. Die Legierungen 2091-T8X und 6061-T4 sind anfällig für interkristalline Spannungsrißkorrbsion. Eine geringfügige Anfälligkeit wird bei der Legierung 6013-T6 gefunden. Für diese Legierung zeigen fraktographische Untersuchungen transkristalline Spannungsrißkorrosion, die auch bei der Legierung 6061-T4 beobachtet wird, wenn die Zugproben mit Dehnraten kleiner 5 · 10-7 s-1 geprüft werden. Die benutzte 3%ige NaCl Lösung mit Wasserstoffperoxidzusatz fördert Lochfraß und interkristalline Korrosion. Der dadurch verursachte Duktilitätsverlust der Zugproben stört bei der Beurteilung der Ergebnisse der Prüfung mit langsamer Dehnrate.
    Notes: The stress corrosion cracking (SCC) behaviour of aluminium alloy sheet was investigated in the long transverse direction using the slow strain rate testing technique. The synthetic environment used was an aqueous solution of 3% NaCl + 0.3% H2O2. No indications of SCC sensitivity are observed for the alloys 2024-T351, 8090-T81, and 2091 CPHK-T8X. The alloys 2091 T8X and 6061-T4 are found to be susceptible to intergranular stress corrosion cracking. At strain rates below 4 · 10-7 s-1, the slow strain rate testing technique indicates a slight SCC sensitivity with alloy 6013-T6. Fractography reveals transgranular stress corrosion cracking. Transgranular stress corrosion cracking is also observed with 6061-T4 specimens which are dynamically strained at strain rates below 5 · 10-7 s-1. Aqueous 3% NaCl solution with hydrogen peroxide addition promotes pitting and intergranular corrosion. The loss of ductility caused by these corrosion processes interferes with the evaluation of the results of the slow strain rate testing technique.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    Surface and Interface Analysis 24 (1996), S. 137-141 
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The adsorption of Cl2 on Cu{111} at 300 K has been studied using shadow-cone-enhanced secondary ion mass spectrometry (SIMS). The system has been investigated for chlorine coverages ranging from 0.08 to 0.33 monolayer (ML), including the Cu{111}-(√3×√3)R30°-Cl surface. The secondary Cu+ ion intensity has been measured as a function of the incidence angle of the primary ion beam. The enhanced intensity features in the spectra are compared with results from a two-body interaction calculation that uses the Molière approximation to the Thomas-Fermi potential. A chlorine-copper interlayer spacing of 1.87±0.04 Åis measured between the coverages of 0.17 and 0.33 ML. This value corresponds to a chlorine-copper bond length of 2.38±0.04 Å. At 0.08 ML, the chlorine-copper bond length is expanded to 2.48±0.04 Å. These results suggest that the chlorine-copper bond is more ionic in the low coverage limit.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Archives of Insect Biochemistry and Physiology 28 (1995), S. 291-309 
    ISSN: 0739-4462
    Keywords: juvenile hormone ; methoprene ; pyriproxyfen ; fat body ; locust ; binding protein ; receptor ; Chemistry ; Food Science, Agricultural, Medicinal and Pharmaceutical Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology
    Notes: Juvenile hormone (JH) binding components from the fat body of the African migratory locust were analyzed in a search for a potential nuclear JH receptor. Biosynthetically prepared 10R[3H]JH III gave a high proportion of specific binding to isolated nuclei and extracted proteins; data obtained with the JH analogs, [3H]methoprene and [3H]pyriproxyfen, on the other hand, were obscured by abundant non-specific binding. The vast majority of the high affinity JH III binding activity present in cytosolic and nuclear extracts was due to a high molecular weight JH binding protein (JHBP) which has previously been identified in locust hemolymph. This protein has several chromatographic forms which interfered in the search for a nuclear JH receptor. When specific antiserum was used to remove JHBP from nuclear extracts, a novel JH binding activity (NBP) was detected. NBP could be separated from JHBP by precipitation with ammonium sulfate. NBP displayed a high affinity for JH III (Kd = 0.25 nM) and JH I and JH II competed strongly for JH III binding, whereas methoprene and pyriproxyfen showed apparent competition when present in 1,000-fold excess. NBP was present in nuclear extracts at approximately 25,000 sites per cell; levels were similar in male and female locusts and were not greatly affected by the presence or absence of JH. The characteristics of NPB make it a strong candidate for a nuclear JH receptor. © 1995 Wiley-Liss, Inc.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...