Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles: DFG German National Licenses  (9)
  • Polymer and Materials Science  (7)
  • Life and Medical Sciences  (2)
Source
  • Articles: DFG German National Licenses  (9)
Material
  • 1
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 12 (1978), S. 541-555 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The corrosion of carved, burnished, polished, and burnished-polished samples of a conventional spherical amalgam was studied by anodic polarization in Ringer's solution. The effect of the variation of the mercury content from 40 to 60 wt% on the corrosion of burnished or polished samples was also investigated. It was found that burnished and burnished-polished samples corrode the least and carved samples the most. The current-density peak associated with γ2 was of greater magnitude in polished specimens than in burnished specimens throughout the range of mercury concentrations investigated. It is hypothesized that lower porosity and more ready passivation of the surface due to a high amount of γ2 are the reasons that burnished samples corroded less than polished samples in this anodic polarization test.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 23 (1989), S. 819-831 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: This study was conducted to investigate some fundamental fatigue testing variables as they apply to the response characteristics of acrylic bone cement. Cyclic loading under load control was conducted at frequencies of 1, 2, 5, 10, and 20 Hz in air at room temperature. At a tensile stress range of 0.3-20.0 MPa the fatigue life increased linearly with logarithmic frequency. The effect of conditioning and testing in saline at both room temperature and 37°C at similar stress levels and a frequency of 10 Hz were also examined. When compared to dry testing at room temperature, testing in saline at 37°C resulted in a reduction in fatigue life while testing in saline at room temperature produced an increase in fatigue life. Of a number of statistical distributions considered, the Weibull was found to be the most appropriate in documenting the findings of this investigation. A companion fractographic investigation of the failure surfaces demonstrated distinct regions of crack growth and fast fracture.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Chemistry Edition 20 (1982), S. 575-582 
    ISSN: 0360-6376
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The hindered amine-induced decomposition of polypropylene hydroperoxide was studied in the solid state and in the presence of a liquid solvent and the polymer was compared with model hydroperoxides. The high reactivity of the macrohydroperoxides appears to be related to the adjacent, hydrogen-bonded hydroperoxide groups that occur in the polymer. The hindered amines are converted to nitroxides in the reaction via hydroxylamine intermediates. Amine-induced decomposition of polypropylene hydroperoxide is faster in the absence of a liquid solvent for the amine than in the presence of the solvent, probably because of the strong amine-hydroperoxide association that occurs in the solid state. The decomposition process in the solid state is sufficiently rapid for the reaction to contribute to the effectiveness of hindered amines in the light stabilization of polymers.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Polymer Science 58 (1962), S. 545-552 
    ISSN: 0022-3832
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Dilatometric data for the glass transition temperature Tg of poly(4-methyl-1-pentene) (PMP) have been extended to more crystalline samples and rendered more precise. Tg is definitely shown to decrease with increasing degree of crystallinity, an effect which tentatively is related to increasing free volume of the amorphous part of the polymer as the less dense crystalline phase increases and pulls apart the polymer chains in the amorphous regions. Tg is determined to be 14 ± 2°C. for 78% crystalline PMP, and 25 ± 2°C., for amorphous polymer. The existence of a higher-order transition at 125 ± 10°C. is confirmed by x-ray measurements and ascribed to transverse chain segment motion.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Polymer Science 61 (1962), S. S29 
    ISSN: 0022-3832
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Letters Edition 18 (1980), S. 607-612 
    ISSN: 0360-6384
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 16 (1995), S. 307-316 
    ISSN: 0197-8462
    Keywords: thermography ; temperature ; phantom ; dielectric properties ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The possibility of tissue heating due to an auditory brainstem implant (ABI) or a modified cochlear implant (CI) during magnetic resonance imaging (MRI) of the head was tested on a full-sized human phantom using a realistic phantom head consisting of simulated skull, brain, and muscle. Dielectric properties of the brain, muscle, and bone materials were similar to those of human tissues at 64 MHz. The body consisted of homogeneous phantom muscle enclosed in a human-shaped fiberglass shell. Thermographic and fiber-optic temperature measurements were conducted to reveal any heating. Thermograms of sagittal, frontal, and horizontal planes of the head with the ABI and CI electrodes were taken immediately before and after a 26 min MRI scan. The MRI sequence was set at 94 excitations and 25 ms echo time to induce maximum radiofrequency heating, as suggested by the General Electric Company. The difference of these two thermograms gives the heating results. In two uncut phantom heads, Teflon tubes were placed along the implanted ABI and CI, and temperature data were recorded via fiber-optic probes before, during, and after the MRI. Results showed no observable heating associated with the ABI and the modified CI during worst-case MRI of the head. © 1995 Wiley-Liss, Inc.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Letters Edition 19 (1981), S. 549-554 
    ISSN: 0360-6384
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Hoboken, NJ [u.a.] : Wiley-Blackwell
    Journal of Orthopaedic Research 5 (1987), S. 217-230 
    ISSN: 0736-0266
    Keywords: Knee joint, biomechanics ; Ligaments, articular ; Buckle transducer ; Life and Medical Sciences
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: Tensions generated in selected bands of the four major ligaments of the flexed knee (40-90°) have been measured in vitro when the tibia is subjected to passive anterior translation and axial rotation with and without a compressive preload. The measurements were made in 30 fresh-frozen specimens using the buckle transducer attached to the anteromedial band of the anterior cruciate ligament [ACL (am)], the posterior fibers of the posterior cruciate ligament [PCL (pf)], the superficia fibres of the medial collateral ligament [MCL (sf)], and in the total lateral collateral ligament (LCL). Particular attention was placed on the evaluation of the performance of the transducer specific to such measurements in order to minimize the errors associated with the use of this transducer. The results indicate that, among the measured ligaments, substantial tension (〉20 N) is generated only in the ACL (am) in tibial anterior translation up to 5 mm. The tension pattern generated in response to tibial axial rotation, however, is complex and exhibits considerable variation between specimens. In general, both the MCL (sf) and LCL are tensed at all tested flexion angles, with the tension in external rotation being significantly greater than in internal rotation. At 40° of flexion, the ACL (am) bears tension mainly in internal rotation, while at 90° of flexion the PCL (pf) is tensed in both senses of rotation. The response of the LCL shows marked variation among specimens; very small tension (15 N) is generated in internal rotation in 48% of the specimens, and in either sense of rotation in 20% of the specimens. The tension in the ACL (am) in internal rotation is invariably greater in those specimens in which LCL tension is negligible. This correlation between increased ACL (am) function and inadequate LCL restraint appears significant in terms of ACL injury and repair.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...