    Electronic Resource
    Electronic Resource
    Springer
    Der Radiologe 36 (1996), S. 483-488 
    ISSN: 1432-2102
    Keywords: Schlüsselwörter Computertomographie ; Pitch ; Äquivalentdosis ; TLD ; Konversionsfaktoren ; Effektive Dosis ; Key words Computed tomography ; Pitch ; Equivalent dose in man ; Thermoluminescence dosimetry ; Conversion factors
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Computed tomography accounts for a high percentage of the populations exposure to radiation. Every possible means of reducing patient exposure must be considered. Exposure reduction will be most appropriate for organs with large absorption differences, since the accompanying decrease in signal-to-noise ratio will have a smaller effect. It has been shown in the literature that high-contrast details in the lung can be depicted, even with the lowest exposure rates. Therefore, experimental data are presented by means of thermoluminescence dosimetry and calculations using conversion factors to determine the technical parameters to be adopted for achieving the effective equivalent dose close to that of a conventional chest X-ray in two projections. With helical CT (pitch 2, 50 mAs, 120 kV, 5-mm slice thickness) it was possible to reduce the equivalent dose from 9.6 mSv to 0.6 mSv, which is comparable with the exposure in a conventional chest X-ray, measured to be 0.2 mSv.
    Notes: Zusammenfassung Die Computertomographie trägt zu einem hohen Prozentsatz zur Strahlenexposition der Bevölkerung bei. Es muß daher jeder Ansatz verfolgt werden, der eine Reduktion der Dosis möglich erscheinen läßt. Für Organbereiche mit großen Absorptionsunterschieden wird dies am ehesten möglich sein, da das mit einer Dosisreduktion abnehmende Signal-Rausch-Verhältnis hier nur einen geringen Einfluß besitzt. Experimentelle Untersuchungen haben in der Vergangenheit gezeigt, daß die Hochkontrastdetails der Lunge auch mit niedrigen Dosiswerten darstellbar sind. Es wurde daher mittels Messungen mit Thermolumineszenzdosimetern und Berechnungen über Konversionsfaktoren untersucht, mit welchen Technikfaktoren man sich in befriedigender Art und Weise der effektiven Äquivalentdosis einer konventionellen Thoraxuntersuchung in 2 Ebenen nähern kann. Mit einem Spiral-CT (Pitch 2, 50 mAs, 120 kV, 5 mm Schichtdicke) konnte die effektive Dosis von bis zu 9,6 mSv auf 0,6 mSv reduziert werden. Für die konventionelle Thoraxuntersuchung konnte ein Wert von 0,2 mSv ermittelt werden.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-2102
    Keywords: Schlüsselwörter Computertomographie ; Lunge ; Niedrigdosis-CT ; Strahlenexposition ; Rundherd ; Key words Computed tomography ; Lung ; Low-Dose CT ; Radiation exposure ; Pulmonary nodule
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Introduction. Computed tomography is a significant source of medical radiation exposure for populations in Europe. Reduced radiation exposure may be possible with modern CT scanners with an image quality that while less good than before remains acceptable for clinical purposes. The lung appears particularly well suited to investigation with low-dose CT owing to the high contrast between normal and diseased pulmonary parenchyma. Methods. We analysed the diagnostic accuracy of different low-dose CT protocols for the detection of pulmonary nodules using inflation-fixed isolated postmortem lung specimens in a chest phantom. In a comparative patient study diagnostic accuracies of standard-dose CT (120 kV, 250 mAs; slice thickness 10 mm, pitch 1) and low-dose CT (120 or 140 kV, 50 mAs; slice thickness 5 or 10 mm, pitch 1 or 2) were assessed. Results. Preliminary results suggest that low-dose CT protocols with radiation exposure of 10–20 % of that with standard-dose CT can reliably depict soft tissue density pulmonary nodules with a diameter of more than 5 mm and can also demonstrate smaller nodules equally well in many cases. Conclusions. Low-dose CT may frequently be an adequate imaging procedure in a given clinical setting, particularly in young patients with benign disease.
    Notes: Zusammenfassung Die Computertomographie (CT) trägt wesentlich zur medizinischen Strahlenexposition der Bevölkerung bei. Eine Reduktion dieser Strahlenexposition läßt sich vermutlich mit modernen CT-Geräten bei für viele Fragestellungen vertretbaren Einschränkungen der Bildqualität realisieren. Zur Untersuchung mittels solcher Niedrigdosis-CT (NDCT) erscheint die Lunge aufgrund der günstigen Kontrastverhältnisse des normalen und pathologischen Parenchyms besonders geeignet. Wir untersuchten die Treffsicherheit unterschiedlicher NDCT-Protokolle im Nachweis pulmonaler Rundherde an Lungenpräparaten in einem Thoraxphantom. In einer vergleichenden Patientenstudie wurde die Treffsicherheit der Spiral-CT des Thorax mit etablierten Parametern (120 kV, 250 mAs, Schichtdicke 10 mm, Pitch 1) mit derjenigen verschiedener NDCT-Protokolle (120 oder 140 kV, 50 mAs, Schichtdicke 5 oder 10 mm, Pitch 1 oder 2) verglichen. Vorläufige Ergebnisse zeigen, daß diese NDCT-Protokolle mit einer Dosis von 10 bis 20 % der Standard-Dosis CT weichteildichte Lungenrundherde mit einem Durchmesser von mehr als 5 mm zuverlässig nachweisen konnten und auch bei kleineren Rundherden häufig gleichwertig waren. Abhängig von der Fragestellung sollten derartige NDCT-Protokolle v. a. bei jungen Individuen mit benignen Erkrankungen auch in der klinischen Routine eingesetzt werden.