Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 66 (1995), S. 2763-2776 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: We review and present an analysis of the major issues in the design of test mass control systems for laser interferometer gravitational wave detectors. Based on this analysis, we present a design for a computer controlled modular analog servo control system which is well suited to the control of a large number of degrees of freedom in long baseline instruments. The system has been tested on an interferometer using multistage cantilever spring isolators. The system enables simple monitoring, testing, and display of many channels simultaneously, while retaining the advantages of analog proportional-integral-derivative control electronics. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 63 (1992), S. 4154-4160 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A 10-GHz superconducting niobium re-entrant cavity parametric transducer was developed for use in a cryogenic 1.5-tonne Nb resonant bar gravitational radiation antenna. The transducer has a very high electrical Q (6×105 at 4.2 K), and was operated at high cavity fields without degrading the Q. A very high electromechanical coupling between the antenna and the transducer was therefore achieved. The highest coupling attained, constrained by the available pump power, was 0.11. If the transducer were to be operated in conjunction with a wideband impedance matching element, an antenna bandwidth comparable to the frequency of the antenna would be attained. The temperature dependence of the Q of the transducer was in good agreement with theory. At temperatures above about 6 K the Q was degraded by the increase in the BCS surface resistance, while at lower temperatures the Q was limited by radiative losses.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 2435-2442 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The construction and operation of a high-quality factor microwave sapphire resonator transducer coupled to a 1 kHz niobium membrane acoustic oscillator are presented in this paper. A four-stage passive vibration isolation system was included in the design to permit the measurement of the transducer's parametric properties. The isolation system was shown to sufficiently suppress mechanical noise above 100 Hz and an upper limit to the displacement sensitivity of the transducer was measured to be 3.0±0.6×10−16 m/(square root of)Hz. The parametric behavior of the transducer with a single pump readout was measured for several transducer configurations, and the results were found to be in good agreement with theory. The measurements presented here display for the first time the complete parametric behavior in a high electrical Q system, where the transducer's bandwidth is less than the mechanical oscillator's frequency. The high stability and low losses of our system may allow the transducer to be configured as a back-action evasion or quantum nondemolition device. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Groundstation antennas located in Western Australia have been used as elements in the Southern Hemisphere very long baseline interferometry (VLBI) experiment. These commercial antennas of 27.5 and 15 m diameter provide a very economical improvement to the imaging capability of this array and the practice of using such antennas can be extended to other sites in the Southern Hemisphere in preparation for the forthcoming space-VLBI experiments. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 66 (1995), S. 2777-2784 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The Perth Astronomy Research Group has developed an automated supernova search program, using the 61 cm Perth–Lowell reflecting telescope at Perth Observatory in Western Australia, equipped with a CCD camera. The system is currently capable of observing about 15 objects per hour, using 3 min exposures, and has a detection threshold of 18th–19th magnitude. The entire system has been constructed using low-cost IBM-compatible computers. Two original discoveries (SN 1993K, SN 1994R) have so far been made during automated search runs. This paper describes the hardware and software used for the supernova search program, and shows some preliminary results from the search system. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 66 (1995), S. 955-960 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: This paper presents a design for a Fabry–Perot optical frequency reference resonator which utilizes the high dimensional stability of cryogenically cooled sapphire. We show that cryogenic sapphire cavities can achieve substantial improvements in frequency stability compared with room-temperature cavities. The design of a laser stabilization system based on such a resonator is discussed. Estimates of fundamental and practical limitations on the frequency stability of such a system suggest that a fractional frequency stability of 10−16 over integration times from 10 to 104 s is possible. The fundamental limits to stability from quantum shot noise, radiation pressure fluctuations, and thermal noise are overwhelmed by practical limits which arise due to mechanical, thermal, and optical effects. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 65 (1994), S. 3482-3488 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: An all metal multistage low frequency vibration isolator for a laser interferometer gravitational wave detector has been built and tested with a very sensitive accelerometer. Curved cantilever springs are used to form a low frequency compact form of isolation element. Near center of mass suspension of the isolation stages reduces cross coupling between orthogonal directions. The isolator has a low-pass corner frequency of 6.5 Hz vertically and 1.8 Hz horizontally. The system shows low temperature coefficients and absence of creep. Results demonstrate that steel curved springs near their elastic limit do not generate broadband acoustic noise at the 10−15 m /(square root of)Hz level.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 64 (1993), S. 3191-3197 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A modified version of the microwave signal processing system for the 1.5 tonne niobium bar gravitational radiation antenna at the University of Western Australia has been developed and tested during preparations for long-term observation. Among the new features of the system are a noncontacting microwave coupling to the motion transducer, cryogenic low-noise amplification, and automatic carrier suppression with improved long-term stability.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 84 (1998), S. 6523-6527 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: A sapphire monocrystal configured with a parametric microwave readout can potentially monitor the motion of its internal acoustic resonances at the precision governed by quantum mechanical fluctuations. The mechanism of transductance is due to parametric interaction between the electric and acoustic field within the crystal. This mechanism has been tested for the first time, and the theory has been verified by observing the pump frequency dependence of the acoustic quality factor. Because of the extremely low acoustic losses (Q〉107) and electrical losses (Q〉104), measurements were sensitive enough to attain positive verification at room temperature. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 58 (1987), S. 1910-1916 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A 1.5-tonne Nb gravitational radiation antenna is described. Problems associated with a noncontacting magnetically levitated parametric upconverter transducer are discussed, and a system using a bonded microwave reentrant cavity and bonded mechanical impedance transformer is described and analyzed in detail. It is shown that such an antenna can be expected to achieve a noise temperature of ∼1 mK. An ultralow phase noise tunable microwave source for the transducer pump signal is described, as well as precision bonding techniques which yield a mechanical positioning accuracy of 10−6 m, and a reproducibility of 10−8 m.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗