    Electronic Resource
    Electronic Resource
    Palo Alto, Calif. : Annual Reviews
    Annual Review of Biomedical Engineering 6 (2004), S. 1-26 
    ISSN: 1523-9829
    Source: Annual Reviews Electronic Back Volume Collection 1932-2001ff
    Topics: Technology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Palo Alto, Calif. : Annual Reviews
    Annual Review of Biomedical Engineering 6 (2004), S. 1-26 
    ISSN: 1523-9829
    Source: Annual Reviews Electronic Back Volume Collection 1932-2001ff
    Topics: Technology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Catalysis letters 69 (2000), S. 153-156 
    ISSN: 1572-879X
    Keywords: palladium supported MCM‐41 catalysts ; carbonylation ; diethyl carbonate
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract The catalytic activities of palladium supported on Si‐MCM‐41 and Ti‐MCM‐41 catalysts have been studied in the reactions of CO + C2H5ONO. It reveals that copper and titanium used as additives are able to increase the yields of DEC and DEO. The additive copper is favorable to DEO formation, while the additive titanium is favorable to DEC formation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1573-9686
    Keywords: Endothelial cells ; Shear stress ; Intensity gradients ; Actin filaments ; Microtubules
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Technology
    Notes: Abstract Endothelial cells elongate and align with the direction of applied fluid shear stress. Previously, automated methods for analysis of cell orientation distribution have used Fourier- or fractal-based methods. We used intensity gradients in images of control and sheared endothelial cells to measure orientation distributions. Automated measurements of mean orientation and angular deviation compared favorably with manual measurements. There was a significantly greater angular deviation in images of control cells compared with sheared cells. Automated methods were also used to quantify organization of cytoskeletal fibers using the local angular deviation and a measure of the local coalignment of fibers called the coalignment ratio. The local angular deviation of microtubules and microfilaments was significantly smaller in sheared cells compared with control. The coalignment of cytoskeletal fibers was significantly greater in sheared cells. We conclude that image intensity gradients can be used rapidly, accurately, and objectively to measure cell orientation distributions and cytoskeletal filament organization. © 1999 Biomedical Engineering Society. PAC99: 8716Ka, 8717-d, 8719Rr, 8764Rr, 0705Pj
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Annals of biomedical engineering 26 (1998), S. 181-189 
    ISSN: 1573-9686
    Keywords: Cyclic strain ; Endothelial cell ; Mechanical stretch ; Mechanical loading ; Hemodynamic forces ; Strain: device ; Cultured cells ; Strain: biaxial
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Technology
    Notes: Abstract The objective of this study is to design a new apparatus to allow the control of the magnitude and frequency of dynamic stretch applied uniformly to cells cultured on a silicon elastic membrane. The apparatus is designed to produce equi-biaxial dynamic stretches with area changes ranging from 0% to 55% and frequencies ranging from 0 to 2 Hz. Homogeneous finite strain analysis using triangles of markers was performed to compute the symmetric two-dimensional Lagrangian strain tensor on the membrane. Measurements of strain in both static and dynamic conditions showed that the shear component of the strain tensor (Erc) was near zero, and that there was no significant difference between radial (Err) and circumferential (Ecc) components, indicating the attainment of equi-biaxial strain. Bovine aortic endothelial cells were transiently transfected with a chimeric construct in which the luciferase reporter is driven by TPA-responsive elements (TRE). The transfected cells cultured on the membrane were stretched. The luciferase activity increased significantly only when the cells were stretched by 15% or more in area. Cells in different locations of the membrane showed similar induction of luciferase activities, confirming that strain is uniform and equi-biaxial across the membrane. © 1998 Biomedical Engineering Society. PAC98: 8780+s, 8745-k, 8722-q
    Type of Medium: Electronic Resource