Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Electronic Resource  (3)
  • 1995-1999  (3)
  • ESR spectroscopy  (2)
  • Allelic diversity  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Theoretical and applied genetics 92 (1996), S. 340-346 
    ISSN: 1432-2242
    Keywords: Bread wheat ; Allelic diversity ; Gliadins ; Glutenins ; DH lines
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract Wheat storage proteins were evaluated by SDS-PAGE in a population of 206 doubled haploid (DH) lines, produced from a cross between bread wheat cvs Chinese Spring (CS) and Courtot (CT). The analysis of gliadins and high- and low-molecular-weight glutenins gave rise to 11 protein markers between parental varieties. Among these, one each was encoded at the Glu-A1, Gli-A1, Gli-A2, Gli-A5, Glu-B3, Gli-B1 and Gli-D1 loci and four were encoded at the Glu-D3 locus. Only the Gli-A2 marker showed a distorted segregation. A distance of 1.94 cM was evaluated between the Gli-A1 locus and the recently found Gli-A5 locus. Among the DH lines, only nine exhibited an unexpected pattern. The chromosome allocation was determined for almost all the LMW-GS and gliadin bands of CS using nullitetrasomic and ditelosomic lines. Two C LMW-GS were found to be coded by 6DS. Similarly, substitution lines into CT allowed the allelic determination of numerous LMW-GS and gliadin bands. A correspondence between gliadin markers separated in SDS-PAGE and in A-PAGE revealed that the common allele Gli-Aa between CS and CT determined in A-PAGE was able to be separated into two alleles when SDS-PAGE was used.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Pharmaceutical research 14 (1997), S. 810-814 
    ISSN: 1573-904X
    Keywords: formoterol ; radiation treatment ; ESR spectroscopy ; dosimetry ; storage ; HPLC ; degradation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Purpose. Radiation sterilization is becoming increasingly popular for the sterilization of many pharmaceutical products. We have investigated the gamma radiation induced effects on formoterol fumarate by HPLC and ESR spectroscopy. Results and Discussion. Numerical simulation of the evolution of the ESR signal versus dose was performed using linear regression, quadratic fit and power function. The shape of the dosimetric curve is linear in the range 5−30 kGy. Owing to the weak number of free radicals generated during the irradiation, the accuracy of measurements is low. For a dose of 25 kGy, discriminating irradiated from unirradiated samples is possible if the storage period is less than 250 days. The comparison between chromatographic profiles of irradiated and unirradiated samples showed minor differences. Conclusions. From our preliminary results, radiosterilization of formoterol fumarate may be technically feasible. Estimation of the irradiation dose by ESR may be possible but, due to the weak number of free radicals generated during the irradiation, the accuracy of measurements appeared low.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Pharmaceutical research 14 (1997), S. 1192-1196 
    ISSN: 1573-904X
    Keywords: dopamine ; norepinephrine ; radiation treatment ; ESR spectroscopy ; dosimetry ; storage
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Purpose. Radiation sterilization is becoming increasingly popular for the sterilization of many pharmaceutical products. We have investigated the gamma radiation induced effects on dopamine and norepineprine by ESR spectroscopy. Results and Discussion. Equations to describe the evolution of the ESR curves versus doses and time of storage are presented. Linear regression is, for dopamine hydrochloride, applicable for doses ranging from 10 to 25 kGy. Since the radiation dose selected must always be based upon the bioburden of the products and the degree of sterility required, doses in the range 10−25 kGy could be investigated and linear regression would appear to be the least expensive route to follow and gives good results. The comportment of noradrenaline bitartrate is more complex and the use of linear regression would appear more hazardous especially for low doses. For doses higher than 25 kGy, a more general equation is required. Power function using only 2 parameters could give good results but must be validated. Decay kinetics for radicals versus storage were considered. Non-homogenous kinetics with time dependent rate constant and bi-exponential function appeared valid to reproduce the decay of radicals for, respectively, dopamine and norepinephrine. Conclusions. It is worth noting that, at present, ESR is the only technique which proved to be suitable for identification and quantification purposes in irradiated pharmaceuticals. Moreover, other features such as sensitivity, precision, ease and non-destructive readout make ESR superior to other proposed analytical techniques.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...