    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Fire and Materials 17 (1993), S. 25-32 
    ISSN: 0308-0501
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Architecture, Civil Engineering, Surveying , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Three timber-based materials were investigated by subjecting them to a constant uniform heat flux in the range 20-70 kW m-2 using a Cone Calorimeter and the ISO Ignitability Apparatus. The specimens were examined in the vertical and horizontal orientations in the Cone Calorimeter using gas flame pilot, spark pilot and spontaneous methods of ignition. They were also studied using the ISO Ignitability Apparatus in the normal and inverted horizontal orientations using gas flame pilot and spontaneous methods of ignition. The results obtained are compared by specimen, orientation and mode of ignition.
    Additional Material: 16 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Fire and Materials 18 (1994), S. 243-254 
    ISSN: 0308-0501
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Architecture, Civil Engineering, Surveying , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: A protocol based on the flux time product (FTP)1 is used to analyze ignition data obtained from the Cone Calorimeter under an impressed flux in the range 20-70 KWm-2 for different orientations and modes of ignition for conditioned cellulosic materials. The mean, maximum and minimum ignition times are depicted graphically by orientation and mode of ignition. Flux time products, FTP indices, critical irradiances and estimates of the convective heat loss associated with a change in specimen orientation are derived using the mean time-to-ignition data. It is demonstrated that consideration of the thermal thickness of a specimen may not be necessary when the proposed FTP methodology is utilized to determine valid correlations between the time-to-ignition and the incident radiant flux.