Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Electronic Resource  (9)
  • Biochemistry and Biotechnology  (3)
  • Autoradiography  (2)
  • Carbonyl  (2)
  • Clocinnamox  (2)
  • 1
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Journal of Organometallic Chemistry 474 (1994), S. 165-171 
    ISSN: 0022-328X
    Keywords: Carbonyl ; Cluster ; Crystal structure ; Gold ; Osmium
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Journal of Organometallic Chemistry 484 (1994), S. 161-167 
    ISSN: 0022-328X
    Keywords: Alkyne ; Carbonyl ; Cobalt ; Crystal structure ; Tetraynes
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-2072
    Keywords: Key words Apparent in vivo affinity ; Alfentanil ; Antinociception ; Clocinnamox ; Efficacy ; Mu receptors ; Nalbuphine ; NIH 10443 ; Operant responding ; Opioid receptors ; Receptor reserve ; Reinforcement ; Self-administration ; Spare receptors
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  The effects of CCAM, an insurmountable mu opioid receptor antagonist, were studied on the intravenous self-administration and thermoantinociception of alfentanil and nalbuphine, high- and low-efficacy opioid agonists, respectively, in rhesus monkeys. A single dose of 0.1 mg/kg CCAM IV reduced alfentanil’s reinforcing potency in an FR30 TO 45s schedule 10-fold within a 24-h period. The maximum response rates remained essentially unchanged. At 1 mg/kg, CCAM caused a 300-fold shift of the alfentanil dose-response curve and also depressed the maximum response rates. CCAM also blocked insurmountably responding for nalbuphine, which was essentially abolished in two of three animals after a dose of 0.1 mg/kg CCAM and in all animals after 1 mg/kg. The acute insurmountable antagonism of alfentanil and nalbuphine self-administration by CCAM was used to determine the (relative initial) efficacy values of both agonists. Efficacy values, tau, were 391 for alfentanil and 196 for nalbuphine; the apparent in vivo dissociation constants, KA, were 0.16 mg/kg per injection (i.e., 350 nmol/kg per injection) for alfentanil and 0.14 mg/kg (370 nmol/kg per injection) for nalbuphine. In comparison, in a rhesus monkey 50°C warm-water tail withdrawal assay, the tau values were 11 for alfentanil and 0.92 for nalbuphine, and the KA values were 0.2 mg/kg (440 nmol/kg) for alfentanil and 0.15 mg/kg (400 nmol/kg) for nalbuphine. Therefore, it seems that the higher potency of alfentanil and nalbuphine in self-administration as compared to thermal antinociception in rhesus monkeys is predominantly due to a larger efficacy of the same agonist in self-administration (i.e., a larger receptor pool) rather than differences in apparent in vivo affinity.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-2072
    Keywords: Clocinnamox ; Fentanyl ; Irreversible antagonists ; Operant behavior ; Rhesus monkeys
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The antagonist effects of clocinnamox were evaluated against opioid agonists, acting at μ, κ and ∂-receptors, in rhesus monkeys (n=3–4) responding under a fixed-ratio 30 (FR 30) schedule for food delivery. Clocinnamox (0.032–0.1 mg/kg) dose-dependently antagonized fentanyl (0.001–0.32 mg/kg) after either a 3-h or 1-day pretreatment; there was substantial recovery of agonist potency by 1 week after clocinnamox. Etonitazene (0.0001–0.01 mg/kg) was also antagonized by clocinnamox (0.1 mg/kg), but to a lesser extent than fentanyl. The smaller extent of antagonism was not due to the appearance of non μ-opioid response-decreasing effects of etonitazene, since the competitive antagonist quadazocine (0.1 mg/kg) shifted the etonitazene dose-effect curve in the presence of clocinnamox (0.1 mg/kg). Clocinnamox (0.1–0.32 mg/kg) did not antagonize the rate-suppressing effects of the ∂-agonist BW373U86 (0.0.01-1.0 mg/kg) or the κ-agonist U69,593 (0.001–0.032 mg/kg). These results are consistent with previous in vivo and in vitro evidence that characterized clocinnamox as an insurmountable antagonist, with selectivity for μ-over κ- and δ-receptors.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 61 (1998), S. 127-134 
    ISSN: 0006-3592
    Keywords: matrix-assisted laser desorption/ionization ; electrospray ionization mass spectrometry ; cyclosporin A ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: This article describes the use of two mass spectrometric techniques, matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI) mass spectrometry, toward a variety of challenging problems in drug discovery and identification. Quantitative ESI was used to screen for inhibitor activity of two different enzymatic glycosylation reactions resulting in the identification of the most effective inhibitors and the determination of their IC50 (inhibitor concentration at 50% inhibition). Also described is a combinatorial extraction method used with automated MALDI mass spectrometry to improve upon the clinical analysis of the immunosuppressant drug cyclosporin A (CsA). Optimization was performed by generating an array of solvent systems which were screened (by MALDI-MS) for the most efficient extraction of CsA from whole blood. Ultimately a 70/30 hexane:CHCl3 mixture was identified as the most efficient binary solvent system for such extractions. In addition it was demonstrated that peptides and carbohydrates, covalently linked to a polymeric support (through a photolabile linker), can be directly analyzed by MALDI in a single step which requires no pretreatment of the sample to induce cleavage from the support. The UV laser light in the MALDI experiment was used to simultaneously promote the analyte's photolytic cleavage from the solid support and its gas phase ionization for subsequent mass spectral analysis. Overall, the strength of mass spectrometry lies in its versatility, making it a powerful analytical technique with which to characterize the diversity of compounds found in combinatorial libraries. © 1998 John Wiley & Sons, Inc. Biotechnol Bioeng (Comb Chem) 61:127-134, 1998.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1059-910X
    Keywords: Electron microscopy ; Autoradiography ; Maximum-likelihood estimation ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Natural Sciences in General
    Notes: The maximum-likelihood (ML) method for the quantitative analysis of electron-microscopic autoradiographs has been shown to be substantially superior to the conventional crossfire (CF) method. It can generate reliable and accurate tracer concentration estimates with far fewer micrographs and produce valid estimates even at counts low enough to preclude the use of the crossfire method while eliminating the need for special ad hoc treatment of narrow membranous structures as well as the secondary verification of the tracer concentration estimates.Despite these significant advantages, the large computational requirements of the ML method has to date hampered its widespread use. In this paper, we present a new line-integration method that allows us to reduce the computational requirements of the ML method to a point where it becomes feasible to implement it on a small computer system of the type typically available to a laboratory user of EM autoradiography. We present the complete line-integration method for the particular case of EM autoradiography with tritium, and show how it can be adapted to other isotopes.We have constructed a software package that implements the complete maximum-likelihood method on the IBM PC class of machines using our line-integration method. Features of this software package which are of particular importance to the research community are device independence, which makes it usable with a large variety of currently available laboratory equipment, and easy portability of the software and data between different computer systems.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 0268-2575
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 0173-0835
    Keywords: DNA sequencing ; Filter matrix ; Clustering ; Calibration ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: In a previous paper (Yin et al., Electrophoresis 1996, 17, 1143-1150), an automated method for matrix determination in four-dye fluorescence-based DNA sequencing was presented. As a continuation of that work, we have developed an alternative method to estimate the matrix from raw sequence data. The method uses an iterative clustering technique to associate each 4 × 1 data vector with one column of the desired filter matrix, using Kullback's I-divergence as a distance measure. The method requires less preprocessing of the data and less computation than the approach described by Yin et al. (Electrophoresis 1996, 17, 1143-1150). An example demonstrating applicability of the proposed method to Applied Biosystems sequencer data is given.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 0741-0581
    Keywords: Autoradiography ; Image processing ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Natural Sciences in General
    Notes: EMAMAP is a program for the data acquisition phase of maximum-likelihood analysis of electron microscope autoradiographs. This program is written in C and has been implemented on a Masscomp MC-500 which supports a graphics processor and a digitizing tablet. The image analysis is automated at a low level: the program operator outlines the edges of the structures of interest using the digitizing tablet, while contiguous regions formed by closed contours are automatically filled by the software. The resulting image is compressed for efficient storage by a quadtree encoding technique for which data compression ratios of greater than 25:1 have been achieved. In practical terms this implies that the data from a typical experiment of 50 autoradiographs could be stored on a single floppy disk. The system is currently in use for acquiring actual biological experimental data.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...