Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1433-2965
    Keywords: Incidence ; Morphometry ; Prevalence ; Sensitivity ; Specificity ; Vertebral fracture
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The absence of specific criteria for the definition of vertebral fracture has major implications for assessing the apparent prevalence and incidence of vertebral deformity. Also, little is known of the effect of using different criteria for new vertebral fractures in clinical studies. We therefore developed radiological criteria for vertebral fracture in women for assessing both the prevalence and the incidence of vertebral osteoporosis in population and in prospective studies and compared these with several other published methods. Normal ranges for vertebral shape were obtained from radiographs in 100 women aged 45–50 years. These included ranges for the ratios of anterior/posterior, central/posterior and posterior/predicted posterior vertebral heights from T4 to L5. The predicted posterior height was calculated from adjacent vertebrae. In contrast to other methods, our definition of fracture required the fulfilment of two criteria at each vertebral site, and was associated with a lower apparent prevalence of fracture in the control women due to a lower false positive rate. The prevalence and incidence of vertebral deformity using different criteria were then compared in a series of women with skeletal metastases from breast cancer in whom radiographs were obtained 6 months apart. The prevalence of vertebral deformity and the specificity for deformity varied markedly with differing criteria. Using a cut-off of 3 standard deviations the prevalence of vertebral deformity in the women with breast cancer was 46%. Using other methods, the prevalences of deformity ranged from 33% to 74%. Over a 6-month interval 25% of patients with breast cancer sustained 61 deformities using our method, of which only 8% resulted from errors in reproducibility. The number of patients sustaining new deformities was increased twofold when assessed by other methods (45%–53%), but errors of reproducibility may have accounted for 21% of the new deformities. The magnitude and distribution of these errors have important implications for the apparent therapeutic efficacy of agents in clinical trials of osteoporosis. The rapid semi-automated technique for assessing vertebral deformities on lateral spine radiographs that we have developed has a high specificity, and reduces the impact of errors of reproducibility on estimates of prevalence and incidence. The method should prove a value in assessing vertebral deformity both in population studies and in prospective clinical trials.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1433-2965
    Keywords: Bone density ; Fractures ; Hormone replacement ; Oestrogens ; Progestogens
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract It is now accepted that unopposed oestrogen therapy reduces osteoporotic fractures by about 50%. Although current regimes with added progestogens are thought to act similarly to unopposed oestrogens, no study has yet demonstrated an effect on fractures with the former. Using a retrospective cohort design we studied fracture rates in women attending a menopause clinic for hormone replacement therapy (HRT) and compared them with women derived from the general population. Data were analysed from 1075 women exposed to HRT and 1741 non-exposed postmenopausal women. In all 226 fractures were reported between 1977 and 1986, the commonest site being the distal radius, occurring in 28 of the HRT women and in 37 of the non-exposed women. The incidence density rate for fracture of the distal radius is 3.5/1000 woman-years (wy) in non-exposed women. This was similar to the rate in the HRT womenprior to HRT use, the rate falling by 30% after exposure from 3.2 to 2.2/1000 wy. The protective effect on osteoporotic fractures increased progressively with duration of use. After 5 years of use the relative risk fell to 0.5 (95% confidence interval, 0.2–1.2) for all osteoporotic fractures and for the distal radius to 0.18 (95% confidence interval, 0.05–1.3). No similar changes were seen for non-osteoporotic fractures. There were 6 (0.6/1000 wy) reported fractures of the hip in the non-exposed group compared with none in the HRT group (when 1.7 were expected based on non-exposed rates) (p=0.15). Although based on observational data, this study suggests that modern HRT regimes are effective in preventing distal radius fractures and potentially other osteoporotic fractures.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...