Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Electronic Resource  (2)
  • Immunosuppressive agents  (1)
  • cyclosporin blood concentrations  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Pediatric nephrology 7 (1993), S. 567-573 
    ISSN: 1432-198X
    Keywords: Immunosuppressive agents ; Transplantation ; Cyclosporine
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Pediatric transplantation has always been challenging for transplant surgeons. Although the higher immunoreactivity and the faster metabolism showed by this unique population when compared with adults requires a heavy immunosuppressive regimen, the possibility of disrupting the delicate balance of correct psychophysical development calls for a regimen of more selective and less toxic immunosuppressive drugs. In the past decade several new drugs have been investigated and some of them appear to be very promising, although pleiotropic toxicities have not yet been eliminated. An appropriate pharmacokinetic approach and the evaluation of synergistic multi-drug combinations by rigorous mathematical models would lead to highly selective immunosuppressive regimens which may result in virtually no toxicity.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-904X
    Keywords: cyclosporin blood concentrations ; acute renal graft rejection ; therapeutic cyclosporin monitoring ; cyclosporin analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract While cyclosporine is recommended to be used only in conjunction with monitoring of its blood concentrations, the utility of these measurements in preventing treatment failure is not established. In a group of 52 patients trough levels and steady-state concentrations were monitored in serum and whole blood by specific (SP) and nonspecific (NS) assays (polyclonal radioimmunoassay, PR; fluorescence polarization immunoassay, FP; high-pressure liquid chromatography, HP). From as many as 10 determinations of trough level and steady state concentrations during the first 40 days after renal transplantation, the lowest measurement was selected. In the case of an acute rejection episode within that time period, only values until that event were considered. Trough level measurements in serum by PR/NS and by FP/NS and in whole blood by HP/SP were not significantly different between patients with and patients without rejection episodes. However, simultaneously measured steady-state values (serum/PR/NS and serum/FP/NS) were significantly lower in patients suffering from rejection (with rejection SS/ serum/PR/NS mean = 127 ng/ml, SD = 41 ng/ml; without rejection mean = 163 ng/ml, SD = 60 ng/ml; P = 0.027, t test). This difference could not be demonstrated for steady state/whole blood/HP/SP measurements. A logistic regression analysis demonstrated that the probability of rejection can be decreased by up to 40% if steady state/serum/PR/NS or steady state/serum/FP/NS values never drop below 250 ng/ml early after renal transplantation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...