Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Electronic Resource  (6)
  • Pharmacokinetics  (3)
  • critical point  (3)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    International journal of thermophysics 15 (1994), S. 1323-1331 
    ISSN: 1572-9567
    Keywords: critical point ; electrical resistivity ; enthalpy ; high pressure ; high temperature ; iron ; liquid metals ; melting ; specific heat ; vapor pressure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Wire-shaped iron samples are resistively volume heated as part of a fast capacitor discharge apparatus. Measurements of current through the specimen, voltage across the specimen, radiance temperature, and thermal expansion of the specimen as functions of time allow the determination of specific heat and various dependencies among enthalpy, electrical resistivity, temperature, and density for liquid iron up to 5000 K. High pressures. up to 3800 bar, are used to obtain the liquid state far above the normal boiling point. An estimate of critical-point data for iron is given by using experimental data of the vapor pressure of liquid iron.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    International journal of thermophysics 17 (1996), S. 987-1000 
    ISSN: 1572-9567
    Keywords: critical point ; electrical resistivity ; enthalpy ; high pressure ; high temperature ; liquid metals ; zinc
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Wire-shaped zinc samples were resistively volume heated as part of a fast-capacitor discharge circuit. Time-resolved measurements with submicrosecond resolution of the current through the specimen, the voltage drop across it, and the thermal expansion of the specimen as a function of time allow determination of the enthalpy, electrical resistivity, and density at different temperatures up to superheated liquid states of zinc far above the normal boiling point. High static pressures, up to 3800 bar of the ambient medium water, were used. An estimate of the critical pressure for zinc is given by investigations of the stability of the sample with a framing CCD camera, taking pictures of different samples varying the ambient static pressure. The critical volume and the critical temperature are obtained by means of an extrapolation of measured data at different pressures.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    International journal of thermophysics 20 (1999), S. 1289-1297 
    ISSN: 1572-9567
    Keywords: critical point ; electrical resistivity ; enthalpy ; gold ; high pressure ; high temperature ; liquid metals
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Wire-shaped gold specimens are placed in a new, improved high-pressure vessel, which is part of a fast capacitor-discharge circuit and in which static pressures above 600 MPa can be reached with distilled water as the pressure-transmitting medium. The specimens are self-heated resistively by a current pulse. The current through the specimen, the voltage drop across it, and its temperature are recorded as a function of time with submicrosecond resolution. The radial expansion of the specimen is determined with a CCD camera, Experiments are performed at different pressures. When the critical pressure is exceeded, there is no liquid–gas phase transition; hence, no sudden change in the thermal expansion rate is observed. The results for temperature, pressure, and specific volume at the critical point of gold are as follows: T c =7400±1100 K, p c=530±20 MPa, and v c=0.13±0.03 × 10−3m3·kg−1.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 561-565 
    ISSN: 0935-6304
    Keywords: Liquid chromatography, HPLC ; Pharmacokinetics ; Quantification in human plasma ; Bronchosecretolyticum ; Separation from metabolites ; Ambroxol ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The bronchosecretolytic drug ambroxol can be reliably quantified in human plasma by high performance liquid chromatography. Plasma is buffered alkaline, extracted with ether, and the organic solvent back-extracted with diluted acid. An automatically sampled aliquot is separated by reversed phase HPLC; the analyte is well separated from two metabolites that interfered strongly in earlier methods. UV detection at 230 nm enables a lower limit of quantitation of 5 ng/ml. Internal standardization with propranolol allows accurate and precise quantification. Evaluation of the optimized combination of mobile and stationary phase is described, and application of the method to experimental and clinical pharmacokinetic studies is illustrated.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 102-105 
    ISSN: 0935-6304
    Keywords: Liquid chromatography, HPLC ; Pharmacokinetics ; Quantitation in human serum ; Antidiabeticum ; Glibenclamide ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The antidiabetic drug glibenclamide can be reliably quantitated in human serum with high performance liquid chromatography. The serum is buffered and extracted with toluene. The organic solvent is evaporated, the residue dissolved in the mobile phase and an aliquot sampled automatically and chromatographed. UV-detection at 229 m allows a lower limit of quantitation of 5 ng/ml. Precise handling of exact volumes facilitates external calibration. Statistical data for imprecision and inaccuracy are given and illustrate reliable quantification. Application of the method to experimental and clinical pharmacokinetic studies with specific problems is illustrated.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 10 (1987), S. 659-664 
    ISSN: 0935-6304
    Keywords: Liquid chromatography, HPLC ; Quantification in human plasma and urine ; Pharmacokinetics ; Subanogram sensitivity ; Metoclopramide ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An optimized HPLC method for the quantification of metoclopramide (MCP) in human plasma and urine is described. MCP and internal standard are extracted from alkalinized substrate into diethyl ether and back-extracted into dilute acid. The analytes are separated with a ternary mobile phase at cyanopropyl-silica and detected at 312 nm (UV detection). The lower limit of quantification is 0.5 ng/ml in plasma and 50 ng/ml in urine. Optimization of extraction, chromatography, and detection is discussed. The method is selective to numerous common drug substances with excellent accuracy and precision data. After validation, the method is applied to the samples of a pharmacokinetic study. Pharmacokinetic parameters indicate the need for a sophisticated method as tool for optimization of metoclopramide formulations.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...