Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1985-1989
  • 1970-1974  (3)
  • 1900-1904
  • 1973  (3)
  • Polymer and Materials Science  (3)
  • survival
Material
Years
  • 1985-1989
  • 1970-1974  (3)
  • 1900-1904
Year
Keywords
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 17 (1973), S. 2519-2522 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The radiation-induced grafting of a series of monomers onto a wide range of paraffin waxes was attempted. Although no grafting could be achieved and only homopolymers were formed, the rates of homopolymerization were greatly enhanced in the presence of the wax. This phenomenon is ascribed to processes of energy transfer from the irradiated wax to the monomer.
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 7 (1973), S. 235-249 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Since the accidental rediscovery of the endosteal implant by Formaggini in the late 1940's, the field has witnessed a tremendous evolution in theory and clinical application. Chercheve, in his efforts to improve on earlier spiral designs, proposed several theories on the relationship of the metallic endosteal implant to its osseous environment. Some of the problems he experienced still have not been overcome in our present designs.The development of the blade implant marked a true advancement in endosteal design. This implant proved to be much more functional and reliable than the spiral concept; however, it too had certain disadvantages which became obvious after a relatively short period of clinical trial. The anchor endosteal implant was developed as a result of efforts to correct the various problems associated with the blade.Preliminary animal research using both anchor and blade implants was begun. Four dogs had each type of implant inserted in edentulous areas. The animals were sacrificed four months post insertion for histologic examination. More sophisticated animal implant studies are being performed at the Brookdale Hospital Medical Center.Clinical evaluation of the anchor implant over a 3-year period has been very encouraging. Results have indicated a higher level of clinical success than previously achieved with blade or spiral designs.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Chemistry Edition 11 (1973), S. 2681-2690 
    ISSN: 0360-6376
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The radiation-induced copolymerization of isobutyl vinyl ether with trichloroethylene was investigated in the temperature range from -50°C to 100°C over a wide range of comonomer compositions. A copolymer was obtained in which the monomers alternate with regularity along the polymer chain over essentially the entire range of comonomer compositions. Both the rate of copolymerization and the number-average molecular weight of the resulting copolymer were found to depend strongly on the initial comonomer composition. The monomer reactivity ratios were determined and correspond well with calculated values. An apparent activation energy of 3.2 kcal/mole was obtained for the copolymerization process which exhibits a dose rate dependence of 0.72. The number-average molecular weight was found to be strongly dependent on the irradiation temperature, reaching a maximum value at 5°C.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...