Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1980-1984  (3)
  • 1980  (3)
  • Automated electrocardiogram interpretation  (1)
  • Catecholamine distribution  (1)
  • Organic Chemistry
  • Ultrastructure
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Psychopharmacology 67 (1980), S. 119-123 
    ISSN: 1432-2072
    Keywords: Catecholamine distribution ; Regional catecholamine levels ; Microwave irradiation ; Brain tissue structure ; Histological examination ; Electron microscopy ; Light microscopy ; Tissue disruption
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Recently we reported regional levels of norepinephrine and dopamine in rat brain following microwave irradiation. In our report, we also compared these levels with those of norepinephrine and dopamine following decapitation. Catecholamine levels following exposure to microwave irradiation significantly increased in several areas. However, whether these increases resulted from compound transfer associated with tissue disruption due to high intensity microwave irradiation was not determined. Sections of corpus striatum and locus coeruleus were examined with a light microscope and the interface of the striatum and the cortex showed no trace of tissue breakdown. Transformed cells, vacuolation, and indications of pyknotic degeneration in the nucleus were found in locus coeruleus after irradiation, but the shapes of these cells were well-defined. Electron microscopic photographs of synapses in the same are showed membrane damage after exposure for 5 s at 1.3 kW, but synaptic vesicles were clearly defined. It was concluded that the increased catecholamine levels were not the result of tissue disruption following rapid heating of the brain by irradiation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0018-019X
    Keywords: Chemistry ; Organic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Photochemistry of Conjugated γ,δ-Epoxyenones: The Influence of a Hydroxy Substituent in ∊-PositionOn 1n, π*- or 1π,π*-excitation (λ ≥ 347 or λ=254 nm), the ε-hydroxy-γ;,δ-epoxyenone 8 undergoes fission of the C(γ)—O bond followed by the cleavage of the C(δ)-C(ε) bond. This hitherto unknown sequence of reactions is evidenced by the structure determination of the new type products 10-17 and 25, including a synthetic proof for 12 and the X-ray analysis of 11 (X-ray data: triclinic P1; a=7,386(2), b=8,904(4), c=9,684(5)Å; α=82,29(4)°, β=74,46(3)°, γ=82,29(3)°; Z=2).The selective 1π,π*-excitation also induces competitive C(γ)-C(δ) bond cleavage to yield the bicyclic acetal 18 and a ketonium-ylide intermediate a, which photochemically forms a carbene b giving the allene 19 and the cyclopropene 20.On 1n,π*-excitation of the acetate 9 the initial C(γ)-O bond fission is, in contrast to the behaviour of the corresponding alcohol 8, followed by a 1,2-methyl shift affording (E/Z)-28 or by a cyclization-autoxidation process yielding the lactone 29.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1741-0444
    Keywords: Automated electrocardiogram interpretation ; Electrocardiogram computer program ; Electrocardiogram telephone transmission
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract The reliability of the Japanese public telephone facilities to transmit electrocardiograms (e.c.g.) for computer interpretation was assessed. The International Business Machine's (IBM) e.c.g. computer program by Bonner was used. No appreciable distortion of e.c.g. was observed following repeated transmission from hospitals separated by 1000 km. Thirty-four normal and 66 abnormal e.c.g.s. were transmitted twice. Identical results were observed in 97% of normals and 92% of abnormals. Following these fundamental experiments, 1236 patients' e.c.g.s. were transmitted for computer intepretation. The study showed that 98·6% (1219 cases) were technically satisfactory and 1·4% (17 cases) were not. The 17 unsatisfactory cases were classified into ten unreceivable data formats, six inconsistent measurements and one unacceptable noise level. The authors concluded that the Japanese public telephone facilities were acceptable for the transmission of e.c.g.s. for computer interpretation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...