Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999
  • 1985-1989
  • 1980-1984  (2)
  • 1981  (2)
Material
Years
  • 1995-1999
  • 1985-1989
  • 1980-1984  (2)
Year
  • 1
    Electronic Resource
    Electronic Resource
    Copenhagen : International Union of Crystallography (IUCr)
    Acta crystallographica 37 (1981), S. 1874-1877 
    ISSN: 1600-5740
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Chemistry and Pharmacology , Geosciences , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Documenta ophthalmologica 52 (1981), S. 123-178 
    ISSN: 1573-2622
    Keywords: physiological optics ; astigmatism comparative ophthalmology ; astigmatism surgery ; IOL calculation ; calculator's program ; depth of focus
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The power of an intraocular lens can be calculated before surgery to make the eye emmetropic or ametropic. The physiological mechanism of accommodation however, cannot be restored with an inelastic lens. An increased depth of focus in the implanted eye can be predicted through optical principles alone, if the postoperative ametropia of the implanted eye is a simple myopic astigmatism. This increased depth of focus without accommodation was tested in artificial ametropia and found to be used in nature by the seal. To increase the precision of intraocular lens calculation the average change in corneal power induced at surgery is used to predict the postoperative corneal power. By controlled suture release in the postoperative phase, the amount of induced corneal astigmatism is adjusted to obtain a simple myopic astigmatism. Patients with an intraocular lens and a simple myopic astigmatism as a residual ametropia, are spectacle independent most of the time. They need their glasses only for driving or prolonged reading. The methods used to calculate the postoperative cornea, the post-operative anterior chamber depth and the intraocular lens are described with the corresponding calculator programs for the HP 41C calculator. Clinical results and measurements of the depth of focus are shown in a series of 50 successive implant cases.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...