Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1985-1989  (1)
  • 1980-1984  (1)
  • 1985  (1)
  • 1984  (1)
Material
Years
  • 1985-1989  (1)
  • 1980-1984  (1)
Year
Keywords
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 35 (1984), S. 95-104 
    ISSN: 1432-0649
    Keywords: 42.60B
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We present a detailed analysis of the self-injected Nd:YAG laser which is capable of generating subnanosecond duration pulses with peak powers as high as 200 MW. The model predicts that pulses with durations much shorter than the electrical rise time of the electrooptical switch driver can be obtained. Application of this technique to a conventionally Q-switched Nd:YAG laser allowed us to obtain 550 ps pulses with 120 mJ in a very stable and reliable way.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1588-2780
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Energy, Environment Protection, Nuclear Power Engineering
    Notes: Abstract The methodology of the detection of (n, α) nuclear reactions by means of cellulose nitrate detectors is discussed with special reference to the reliability of the quantitative estimates. The discrimination of10B and6Li from the other isotopes is possible by using thin coloured detectors. The ratio of the number of tracks found at the level of a10B or5Li-enriched calibrating sample, and the number expected from theoretical calculation, i.e. the detection efficiency, P is generally below 1. P is fairly sensitive to the experimental conditions, and for precise quantitative measurements it must be determined separately for each different experiment. The gelatin, used for solidification of liquid samples is boron contaminated (almost 1 μmol natural B per g). It has been observed, especially with10B-enriched liquid samples, that part of the stable tracer under study is lost during sample preparation.6Li extra tracks appear at the rear face of “thick”, non-plastic-supported detectors. Boron diffuses in the cellulose-nitrate detectors with the diffusion coefficient of the order of 10−8 cm2·s−1. Therefore it requires rapid operations for microlocation of boron with high resolving power.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...