Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1471-4159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Abstract: The expression of the 70-kDa heat shock cognate (HSC70) and stress-inducible (HSP70) proteins, and their mRNAs, was examined in experimental autoimmune encephalomyelitis, a model of inflammatory demyelination in the CNS. This study was undertaken as an extension of previous work demonstrating an abrupt decline in mRNA levels of both glial fibrillary acidic protein and the low-molecular-weight neurofilament subunit in experimental autoimmune encephalomyelitis spinal cord at 12 days after inoculation, the height of inflammation and clinical signs. Using the same total RNA preparations as our previous study, we report here that mRNA levels for HSC70 increased approximately sixfold over control values at the same time that glial fibrillary acidic protein and low-molecular-weight neurofilament subunit messages decreased and were similar to controls by 21 days after inoculation. In situ hybridization experiments showed that HSC70 mRNA was predominantly expressed in neurons and that the influx of inflammatory cells into the CNS was not responsible for the large increase in HSC70 message. Despite this elevation in mRNA, only small (if any) increases in protein levels for HSC70 were detected by both western blotting and in vitro cell-free translation systems. However, by quantitative immunoblotting, we determined that constitutive levels of HSC70 comprised a substantial portion of CNS proteins, representing 2–3% of the total protein content of spinal cord. Immunohistochemical staining illustrated that the distribution of HSC70 was consistent with that of its message. In contrast, no HSP70 mRNA or protein was detected in either control or experimental animals.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of medicinal chemistry 18 (1975), S. 523-524 
    ISSN: 1520-4804
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 100 (1994), S. 6240-6262 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: The (0,0) band of the B 4Π–X 4Σ− transition of NbO, near 6600 A(ring), has been analyzed from spectra taken at sub-Doppler resolution. The transition is notable for the great width of its Nb nuclear hyperfine structure, which is caused principally by the unpaired 5sσ electron in the ground state interacting with the large magnetic moment of the 4193Nb nucleus (I=9/2). A fit to the ground-state combination differences, including four very precise microwave lines measured by Suenram et al. [J. Mol. Spectrosc. 148, 114 (1991)], has given a comprehensive set of rotational, spin, and hyperfine parameters. Prominent among these are the third-order spin–orbit distortions of the spin-rotation interaction and the Fermi contact interaction, which are large and well determined, reflecting different degrees of spin–orbit contamination of the the 4Σ1/2− and 4Σ3/2− components of the ground state.The δ 2π B 4Π state was hard to fit, for a number of reasons. First, its spin–orbit structure is asymmetric, because of strong perturbations by a 2Π state which has been identified in this work, from among the various weak bands in the NbO spectrum near 7000 A(ring); the result is that many high order centrifugal distortion terms are needed in an effective Hamiltonian model for the rotation. Second, the hyperfine structure is perturbed, not only by this 2Π state, but by distant Σ and Δ states at higher energy. The δ 2σ* C 4Σ− state at 21 350 cm−1 appears to be one of these. The distant states generate large apparent nuclear spin-rotation interactions, both within and between the Λ components of the Π state, as a result of cross terms between matrix elements of the operators −2BJ⋅L and aI⋅L. Similar cross terms arising from the operators AL⋅S and aI⋅L produce corrections to the Fermi contact matrix elements and are responsible for the unexpected negative sign of the magnetic hyperfine parameter d. The "off-diagonal'' quadrupole parameter e2Qq2 is very large, and causes some of the higher J line shapes of the B–X system to be noticeably asymmetric at Doppler limited resolution; its value is consistent with the electron configuration of the B 4Π state being δ 2π.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 101 (1994), S. 7300-7310 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: High-resolution intracavity dye laser spectroscopy has been used to obtain sub-Doppler spectra of transitions to 350 rotational levels in the 410 band of the A˜ 1A2–X˜ 1A1 electronic transition of thioformaldehyde. Ground state combination differences from the sub-Doppler spectra, combined with microwave and infrared data, have been used to improve the ground state rotational and centrifugal distortion constants of H2CS. The upper state shows a remarkable number of perturbations. The largest of these are caused by nearby triplet levels, with matrix elements of 0.05–0.15 cm−1. A particularly clear singlet–triplet avoided crossing in Ka' = 7 has been shown to be caused by interaction with the F1 component of the 3162 vibrational level of the a˜ 3A2 state. At least 53% of the S1 levels show evidence of very small perturbations by high rovibronic levels of the ground state. The number of such perturbations is small at low J, but increases rapidly beyond J=5 such that 40%–80% of the observed S1 levels of any given J are perturbed by ground state levels. Model calculations show that the density and J dependence of the number of perturbed levels can be explained if there is extensive rotation-induced mixing of the vibrational levels in the ground state.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    BJOG 87 (1980), S. 0 
    ISSN: 1471-0528
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: In 80 patients, multiple measurements of the fetal biparietal diameter were made during one examination using a real-time scanner equipped with a coded cephalometer. From the sets of data, the means and standard deviations for the group of 80 patients were calculated. In 80 per cent of cases, the individual standard deviations of the results were less than or equal to the estimated standard deviation of the group as a whole. The variability of measurement related to biparietal diameter was least in the range 59 to 83 mm. Comparison of the results obtained with the coded device and others obtained ‘blind’ does not reveal any significant advantage for the coded device.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1471-0528
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Summary. Cardiac electromechanical intervals were measured during labour in 103 unselected human fetuses. Mean values (±SD) for the three intervals measured were 76.01±9.93 ms for the pre-ejection period, 41.56±8.51 ms for the isovolumetric contraction time and 156.23±16.58 ms for the left ventricular ejection time. These are consistent with previously reported data from our own and other centres. The intervals studied did not alter significantly as labour proceeded or during uterine contractions. There was no consistent correlation between them and fetal scalp blood P o2,P co2 or pH, although the pre-ejection period was shortened considerably in three very acidaemic or hypoxic fetuses, and it was prolonged in association with tight nuchal cord entanglement and variable decelerations in fetal heart rate. These findings raise the possibility of using recorded cardiac electromechanical intervals to determine the clinical significance of different fetal heart-rate patterns that suggest the possibility of fetal distress.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    BJOG 86 (1979), S. 0 
    ISSN: 1471-0528
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: In a series of 168 patients in the first trimester of pregnancy, fetal crown-rump length (CRL) measurements were attempted in the Antenatal Clinic using a linear-array real-time ultrasound scanner. The measurements could not be made in 23 of the patients; most of them had a gestational age of less than 10 weeks and the difficulty in obtaining measurements was usually due to an underfilled maternal bladder. When compared with CRL measurements obtained with a conventional B-scanner, a good correlation was obtained (r = 0·92); 80 per cent of the‘real-time’values fell within a range of 5 mm of the conventional values. In all patients the estimates of gestational age using the two methods were within one week of each other.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1471-0528
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Summary. Five infertile women, with normal menstrual rhythm who had been investigated previously by daily hormone analyses throughout at least one complete menstrual cycle and had shown poor luteal-phase steroid-hormone profiles were treated by a new approach. They were rendered hypogonadotrophic with large doses of a luteinizing hormone releasing-hormone analogue (Hoe 766) and were then treated with exogenous gonadotrophins to induce follicular growth and ovulation. Progesterone production after ovulation in all cases was superior to that observed in the individual patients’ without treatment. One patient conceived in her first conception cycle and another in her fourth. This regimen offers a systematic approach to the treatment of unexplained infertility in women with deficient luteal-phase steroid-hormone profiles.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1471-0528
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Radiological estimates of gestational age in late pregnancy were compared with the gestational ages based on first trimester ultrasound crown-rump length measurements in a series of 125 patients. It was found that the 95 per cent confidence limits of a radiological estimate were ± 3½ weeks, that both distal femoral and upper tibial epiphyses were frequently present much earlier than 36 and 38 weeks respectively, and that in almost half of the growth-retarded babies in the series there was a bone-age discrepancy of three or more weeks. It is recommended that more liberal use is made of early ultrasound measurements for the assessment of gestational age.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1471-0528
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: In 131 patients a comparison was made between measurements obtained using a real-time scanner and those obtained using a Conventional ‘B’ scanner with an attached ‘coded cephalometry system’: 69 per cent of the readings agreed within ±2 mm and, when the ‘B’ scan reading was considered ‘good’, 90 per cent fell within this range. Between 14 and 28 weeks, gestational age diagnoses using the two methods were within one week of each other in 88 of 89 patients.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...