Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1985-1989  (2)
  • 1985  (2)
Material
Years
  • 1985-1989  (2)
Year
  • 1
    Electronic Resource
    Electronic Resource
    Copenhagen : International Union of Crystallography (IUCr)
    Applied crystallography online 18 (1985), S. 55-60 
    ISSN: 1600-5767
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: The requirements imposed on the magnitude of the noise in a scattering curve in order to minimize the corresponding error in the structure functions are estimated for a given value of the time T in which the scattering curve is recorded. Typical small-angle X-ray scattering (SAXS) curves have been used to check how these conditions are fulfilled when different counting modes are applied for the measurement. It is shown that fixed-time counting is the most practical technique and produces error bands in the structure functions with magnitudes close to the smallest values attainable in SAXS investigations.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Copenhagen : International Union of Crystallography (IUCr)
    Applied crystallography online 18 (1985), S. 205-213 
    ISSN: 1600-5767
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: An improved transform technique has been developed [Gerber (1983). Thesis, Wilhelm-Pieck-University Rostock, German Democratic Republic] for calculating the particle size distribution N(R) for spherical particles with radii R from small-angle X-ray scattering data. This method permits N(R) to be calculated from analytical expressions that were derived for point collimation and for infinitely long slit collimation. A special procedure has been introduced in order to reduce termination errors. The technique described and those developed by Schmidt [Brill, Weil & Schmidt (1968). J. Colloid Interface Sci. 27, 479–492], Vonk [J. Appl. Cryst. (1976), 9, 433–440] and Glatter [J. Appl. Cryst. (1980), 13, 7–11] were used for calculating particle size distributions from theoretical scattering curves and from an experimental scattering curve of suspended SiO2 particles (Ludox). The results obtained by the different techniques were compared, and reasonable results are given by all methods employed. The accuracy of the size distributions calculated by the improved method is somewhat higher than that obtained by Schmidt's transform technique. With Glatter's procedure, the deviations from the exact distributions are comparable to those from this improved transform technique, but the use of Glatter's program requires a large computer, whereas the new method has the advantage of being suitable for a small computer. Vonk's program also requires a large computer, and the deviations obtained are larger than those produced by other methods. The experimental scattering curve of the Ludox sample was also evaluated by assuming a log-normal distribution for the particles. The parameters μ and σ of this function were determined from a set of small-angle X-ray scattering structural parameters. The resulting log-normal distribution is significantly different from the size distribution calculated by our method.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...