Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1985-1989  (3)
  • 1905-1909
  • 1987  (3)
  • Life and Medical Sciences  (2)
  • Carrier-mediated transport  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Annals of biomedical engineering 15 (1987), S. 217-227 
    ISSN: 1573-9686
    Keywords: Pulmonary endothelium ; Carrier-mediated transport ; Michaelis-Menten equation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Technology
    Notes: Abstract The pulmonary endothelium is capable of removing and metabolizing serotonin (5HT) carried in the venous blood. Thus the lungs can influence the arterial concentrations of 5HT. In addition, there is evidence that changes in the lung uptake of 5HT might portend more serious endothelial damage wherein the barrier function of the endothelium is compromised. This has been a stimulus for finding methods for evaluating these endothelial functions. These methods must be able to distinguish changes in whole organ function which result from changes in perfusion (e.g., cardiac output, redistribution of flow, etc.) from those resulting from changes in the function of the endothelial cells. When a bolus containing radio-labeled 5HT and an unmetabolizable indicator which is confined to the vascular space is injected into the pulmonary artery, the pulmonary venous or systemic arterial concentration curves contain information about both the convective transport and endothelial cell process involved. Some of this information can be interpreted quantitatively using a simple mathematical model.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Cellular Physiology 131 (1987), S. 36-42 
    ISSN: 0021-9541
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: Treatment of murine peritoneal macrophages for 30 min with lipopolysaccharide (LPS) resulted in a transient increase in c-fos proto-oncogene mRNA levels (Introna et al., 1986). After 2 h from the initial treatment, c-fos mRNA could no longer be detected and its expression could not be restimulated either by LPS or by other signals including colony stimulating factor-1 (CSF-1) and phorbol myristate acetate (PMA), both of which are able to induce expression of the c-fos gene in unstimulated macrophages. When LPS was removed after an initial 30 min incubation, responsiveness to a second exposure to LPS began to reappear after 3 h and was completely restored by 20 h. The same pattern of desensitization of c-fos induction was observed when CSF-1 stimulated macrophages were subsequently exposed to LPS. The loss of sensitivity to PMA following pretreatment with LPS was selective for c-fos expression as LPS treated macrophages remained responsive to PMA with respect to the ability to stimulate secretion of H2O2. The mechanism of desensitization was localized, at least in part, at the level of transcription as demonstrated by analysis of c-fos transcripts in nuclei isolated from macrophages pretreated and restimulated with LPS.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ [u.a.] : Wiley-Blackwell
    Journal of Orthopaedic Research 5 (1987), S. 150-153 
    ISSN: 0736-0266
    Keywords: Laser Doppler flowmetry ; Blood cell flux ; Cruciate blood flow ; Life and Medical Sciences
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: The purpose of this study was to quantitate the blood flow of the anterior cruciate ligament in vivo. Functional flow was evaluated using laser Doppler flowmetry (LDF), for which the output signal, blood cell flux (BCF), is expressed in terms of volts. Ten patients undergoing routine arthroscopic surgery with clinically intact anterior cruciate ligaments were selected at random for participation in the study. Under arthroscopic visualization, a 2.2-mm probe was placed through a trocar sleeve into the anterior cruciate ligament after the arthroscopic procedure. Pulsatile flow within the ligament was observed in all patients. The mean maximum BCF value ranged from 101 to 274 mV; SD range was + 3-9 mV. The mean minimum BCF ranged from 75 to 197 mV; SD range was + 0 to 9 mV. Laser Doppler flowmetry offers significant promise as a method for measurement of in vivo anterior cruciate and cruciate substitution blood flow.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...