Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1985-1989  (3)
  • 1987  (3)
  • Chemistry  (2)
  • Analytical Chemistry and Spectroscopy  (1)
  • Autocorrelation  (1)
  • 6-thiouric acid
Material
Years
  • 1985-1989  (3)
Year
Keywords
  • 1
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Extensive networks of metastable ions link the major peaks in the electron impact mass spectra of two crown ethers containing 2,6-pyrido units. High-resolution mass measurements and the metastable peaks allow the elucidation of the fragmentation pathways. The spectra are influenced more by the presence of aromatic substituents than by the 2,6-pyrido units.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 25 (1987), S. 241-249 
    ISSN: 1741-0444
    Keywords: Analysis ; Autocorrelation ; Defibrillation ; Performance ; Regression ; Signal ; Ventricular fibrillation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract The paper investigates quantitative differences in the signal characteristics of ventricular fibrillation (VF) and other cardiac arrhythmias. The analysis procedure comprises two steps: calculation of a short-term autocorrelation function (ACF) followed by a regression test on a plot of peak magnitudes of the ACF against lag values (the ACF/lag plot). We detect VF by testing the hypothesis that the ACF/lag plot of VF does not pass a linear regression test. Analysis of 31 separate episodes (of VF and other ventricular arrhythmias), each comprising three successive segments of 1·5s each produced the following results: (1) 100 per cent sensitivity (Se), 62 per cent specificity (Sp) and 74 per cent test efficiency (TE) after analysis of the first segment; (2) 100 per cent Se, 86 per cent Sp and 90 per cent TE after the second segment; and (3) 100 per cent Se, 100 per cent Sp and 100 per cent TE after the third segment. This method quantifies the notion that VF signals are nonperiodic with a random amplitude distribution, whereas ventricular tachycardia (VT) signals are usually periodic with more uniform amplitude distributions. Accurate discrimination and identification of VF can be very important in intensive-care settings, as well as in the design of automatic cardioverters and defibrillators.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 25 (1987), S. 1473-1480 
    ISSN: 0887-6266
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: The translational diffusion coefficients for three relatively short, nearly monodisperse polystyrene chains (with molecular weights 2000, 4000, and 9000) in liquid cyclohexane have been measured up to 523.2 K using the extended Taylor dispersion method. The resultant hydrodynamic radii are successfully interpreted with the freely jointed chain model corrected for the approximations intrinsic to Kirkwood's theory with Stokes' radius as the only adjustable parameter, which is found to decrease with chain length but approach a constant value for long enough chains. The experimentally observed hydrodynamic radii of polystyrene standards with molecular weights 17,500, 50,000 and 100,000 at 308.2 K conform quite well to the values predicted with the approach formulated in this work.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...