Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1985-1989  (3)
  • 1987  (3)
Material
Years
  • 1985-1989  (3)
Year
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 58 (1987), S. 530-535 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A hydrogen beam probing system developed for the REPUTE-1 reversed field pinch device is described. With this system, the plasma ion line density, the central ion temperature, and the magnetic field profile can be measured. Before being applied to the REPUTE-1 device, the probing system was tested on the TORIUT-5 tokamak and TORIUT-6 ultralow-q (ULQ) devices. The experimental results show the availability of the system. The measured line density agrees well with that measured by the microwave interferometry. The measurable density ranges from 1019 m−3 to 3×1020 m−3. A new method of magnetic field measurement which is effective and important for RFP plasmas is proposed. The resolution and the accuracy of this measurement have been confirmed by experiments on the TORIUT-5 device. Experimental results agree well with computation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Physics of Fluids 30 (1987), S. 2465-2469 
    ISSN: 1089-7666
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The spontaneous formation of magnetohydrodynamic (MHD) equilibrium profiles in toroidal current-carrying plasmas has been discussed for tokamaks, reversed-field pinches (RFP's), and also for their intermediate states ultra-low q's (ULQ's). The significance of m (poloidal mode number)=1 fluctuations causing a shift of the magnetic axis is stressed. The characteristics of MHD relaxation have been studied in comparison with classical diffusion. The dynamics of ULQ's is shown to illustrate the characteristics of both dissipative processes. A global-mode stable ULQ is observed to be produced through MHD relaxation, and then to be deformed, in a longer time scale, by classical diffusion which destabilizes the stable profile.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Journal of radioanalytical and nuclear chemistry 118 (1987), S. 225-233 
    ISSN: 1588-2780
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Energy, Environment Protection, Nuclear Power Engineering
    Notes: Abstract Isotope dilution mass spectrometry using enriched isotope96Ru as a spike was applied to the determination of ruthenium as a fission product. Ruthenium in the solution was oxidized to RuO4 by Ce/IV/ and separated from coexisting metal elements by distillation. “Silica-gel technique” was employed to enhance ion current of ruthenium in the mass spectrometric measurement. The lower detection limit was 0.005 μg ml−1 and the relative standard deviations /n=3/ for 1.2 and 0.05 μg ml−1 of ruthenium were 0.2 and 0.5%, respectively.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...