Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Phase-transfer catalysis ; On-line derivatization ; Phenolic steroids
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Commercially available equipment from two manufacturers served to set up an automated system for the precolumn phase-transfer-catalyzed dansylation of phenolic steroids, using ethynyl estradiol (EE) and estradiol (E) as model compounds. Using different mixing techniques, the on-line determination of EE and E in 200μl untreated urine samples was achieved at a rate of 3–8 analyses per hour. Detection limits were calculated to be 3–5 ng/ml. Calibration curves in urine were linear over two orders of magnitude with r=0.999 (n=5) for EE and r=0.999 (n=6) for E. The repeatability of the determination of EE in urine (1μg/ml) was 3.9% (RSD; n=20) and of E (1.5μl/ml) 3.8% (RDS; n=10). The use of plasma instead of urine in the on-line procedures was not possible due to rapid formation of emulsions, but E and EE were determined in 100μl plasma samples using a mild off-line mixing procedure in 10min. Detection limits were calculated to be ca 10ng/ml. A reaction detector, based on a solvent-segmented system, was developed for the on-line post-column dansylation of phenols and was coupled with a reversed-phase LC system. The highly selective system showed excellent linearity over at least two orders of magnitude with r=0.9999 (n=6) for both phenol and 2,5-dimethylphenol. The reproducibility was good with RSD values of around 2%. Detection limits for loop injections from standard solutions were calculated to be between 4 and 11ng.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0935-6304
    Keywords: Coupling LC/GC ; Retention gap ; Polychlorinated biphenyls ; Sediment ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Narrow-bore column liquid chromatography coupled on-line with capillary gas chromatography (LC/GC) is used for the determination of polychlorinated biphenyls (PCBs) in sediment via a heart-cutting technique. This method is compared with a method in which two off-line column clean-up steps are used with subsequent analysis by capillary gas chromatography. For the LC/GC analysis the recovery of PCBs was 90-100%. For two sediment samples from the river Meuse the LC/GC and the other, more laborious method showed good agreement.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...