Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1985-1989  (2)
  • 1980-1984
  • 1989  (2)
  • ANP receptors  (1)
  • Analytical Chemistry and Spectroscopy  (1)
  • 1
    ISSN: 1573-4919
    Keywords: particulate guanylate cyclase ; ANP receptors ; rat lung ; PK1 cells ; physical characteristics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Summary A line of kidney cells (PK,) which does not possess measurable ANP binding but has an active particulate guanylate cyclase has been identified. The physical characteristics of this enzyme were compared with those of particulate guanylate cyclase and ANP receptors isolated from rat lung. Although receptor and enzyme appear to reside on the same protein in the lung while the cyclase from PK1 cells does not possess ANP binding activity, these proteins exhibit identical physical characteristics. Guanylate cyclase from PK1 cells and rat lung and ANP receptor from lung co-eluted during gel filtration chromatography, with a Stokes radius of 6.1 nm. Also, these activities co-migrated through sucrose density gradients with S20,w values of 10.4 to 10.9. Using these parameters, a molecular weight of about 270 kD was estimated for all three activities. Furthermore, these enzyme activities exhibited similar mobilities in isoelectric focusing gels, with a pI of 6.1. Thus, although particulate guanylate cyclase from lung presumably possesses receptor binding activity, it is physically identical to a form of this enzyme associated with no measurable binding activity. Possible explanations for these observations are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 24 (1989), S. 470-478 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The scan modes that can be used to obtain daughter ion, parent ion, and constant neutral-loss spectra on hybrid mass spectrometers are derived for instruments with a quadrupole combined with a magnetic and/or electric sector. All combinations of sector/quadrupole and quadrupole/sector instruments are discussed. The advantages or lack thereof of the various scans are presented with respect to operation, resolution and potential artifacts.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...