Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (7)
  • 1985-1989
  • 1950-1954
  • 1992  (7)
Material
Years
  • 1990-1994  (7)
  • 1985-1989
  • 1950-1954
Year
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 72 (1992), S. 1660-1660 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 71 (1992), S. 4515-4522 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Palladium oxide thin films are studied by ellipsometry, optical transmission, and Raman scattering. The PdO films are made by completely oxidizing Pd films sputtered onto fused silica substrates, and their optical constants determined using a combination of ellipsometry and transmission measurements. Oxidation kinetics experiments are performed on thick Pd substrates at temperatures of 300–500 °C. The optical properties of the films show a thickness dependence suggesting an increased absorption at the PdO-Pd interface. Ellipsometry on oriented single crystals of PdO yields the anisotropic optical constants at 632.8 nm. These results are combined with an effective medium theory to show that the oxidized films have a void density of 20–25%. Raman scattering is demonstrated to be a very sensitive probe for detecting the presence of PdO on Pd. An oxide only a few A(ring) thick is readily detectable, despite the absence of any surface enhanced Raman effect.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1520-4995
    Source: ACS Legacy Archives
    Topics: Biology , Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1439-0523
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition
    Notes: The linkage relationship between eighteen isozyme loci and the morphological markers hypocotyl colour (R-r), monogerm character (M-m), pollen fertility (X) and stem fasciation (Verb.) are tested. Three linkage groups could be set up, involving all morphological marker loci and eight of the isozyme loci. Est-2, R-r, Fdp-2, Got2 and Icd-1 belong to linkage group I, linkage group II includes the loci Fas-fas M-m, Est-3 and Aco-1, linkage group III contains the loci X, Mdh-1 and Est-5.When analysing the inheritance of isozymes and RFLPs, deviations are usually found in some lines from the expected frequencies of a 3 : 1 or 1 : 2 : 1 segregation at single marker loci. In many cases these data can still be used for the estimation of recombination values with linked loci under the control of selection. Procedures to estimate linkage in such cases are given and applied to experimental data in Beta vulgaris.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1432-1440
    Keywords: Insulin action ; Insulin pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary To compare the pharmacokinetics of two different concentrations, containing either 40 or 100 IU/ml of short-acting human insulin (Velasulin HM), intermediate-acting human insulin (Insulatard HM), or an insulin mixture (25% short-acting insulin, 75% intermediate-acting insulin; Mixtard HM), three randomized, single-blind, crossover trials were performed using the euglycemic clamp technique. Eighteen healthy volunteers received insulin of either formulation subcutaneously in each of the studies (15 IU Velasulin, 20 IU Insulatard, or Mixtard). The blood glucose levels were maintained constant by glucose infusions. In the trial using Velasulin, the two different insulin concentrations were equivalent regarding the total absorption [area under the curve (AUC) of serum insulin: 126 ± 28 and 123 ± 35 mU/1 x 12 h for U40 and U100 (x ± SD)], but not in regard to the rate of absorption (t max 1.3 ± 0.4 and 2.4 ± 1.0 h for U40 and U100). In the case of Insulatard, total absorption was not equivalent (AUC 153 ± 35 and 128 ± 37 ml/l x 24 h for U40 and U100), but the rate of absorption was equivalent (t max 4.8 ± 2.9 and 5.3 ± 4.6 h). In the Mixtard series, total absorption was equivalent (AUC 142 ± 32 and 128±22 mU/1 x 24 h), but the rate of absorption was not (t max 2.2 ± 0.9 and 3.2 ± 4.2 h for U40 and U100). The glucose requirement was not equivalent in each of the three series. It was higher for the U-100 formulation in the Velasulin trial (2363±578 ml/12 h for U40 and 2601 ± 820 mi/ 12h for U100) and lower in the Insulatard trial (2203 ± 1271 ml/24 h for U40 and 1864 ± 864 ml/ 24h for U100) and the Mixtard trial (2559 ± 914 ml/24h for U40 and 2067 ± 896 ml/24 h for U100). When switching insulin from U40 to U100 formulations, more frequent blood glucose monitoring in the early phase following the insulin injection is recommended.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    [S.l.] : International Union of Crystallography (IUCr)
    Acta crystallographica 48 (1992), S. 626-639 
    ISSN: 1600-5724
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Chemistry and Pharmacology , Geosciences , Physics
    Notes: It is shown in this paper that the reflectivity of X-rays at smooth and fiat surfaces gives the dispersive correction f′(E) to the atomic form factor with an accuracy comparable to that obtained by X-ray interferometry. A detailed set of values of f′(E) in the energy range 7–27 keV is given for Ni, Cu, CuO, Ta, LiTaO3, Pt and Au, together with the corresponding linear absorption coefficients μ/ρ. Whenever comparison is possible the values of f′(E) agree very well with those obtained by interferometry or by Kramers–Kronig transformation. Data calculated according to Cromer & Liberman [J. Chem. Phys. (1970). 53, 1891–1898] agree well with our data far from absorption edges. At the edges there are substantial differences because the calculations do not take into account the structure of the edges, their chemical shift in compounds and the EXAFS structure above the edges. Below absorption edges the values of f′(E) for metals and their oxides are equal, provided the chemical shift in the position of the edges is taken care of. This feature is interesting in anomalous scattering experiments, where the variation off' with energy is used to vary the scattering contrast of a given atomic species. Once f′(E) is known, X-ray reflectivity measurements can be used to determine the density and the thickness of layers on fiat substrates. In addition, the roughness of the air-layer and layer-substrate interfaces have been determined with high precision in the metals and oxides mentioned above.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 43 (1992), S. 209-210 
    ISSN: 1432-1041
    Keywords: Moxonidine ; Hydrochlorothiazide ; pharmacokinetics ; drug interaction ; steady-state ; healthy volunteers ; adverse effects
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...