Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A neonatal incubator has been custom modified to enable measurement of initial platelet retention on biomaterials in vitro under clinically relevant hemodynamic conditions. To calibrate this device, platelet retention on several materials having microconduit geometry (0.7-1.0 mm i.d.) has been measured after perfusion with citrated whole blood (containing 111 Indium-labelled platelets) at a shear rate of 312 s-1, 37°C, and 80 cm H2O transmural pressure. The relative reactivity of these materials toward platelets was: glass 〈 Fibrinogen(Fg)-coatedglass 〈 Fg-coated polyethylene 〈 polyethylene ∼ = Expanded polytetrafluoroethylene. Interindividual variation is relatively large (coefficient of variation = 35.5 ± 9.3%), but comparison to intraindividual controls reduces the variability to 14.8 ± 10.3%, a level which is suitable for economical testing of platelet retention to biomaterials in the presence or absence of drugs. This approach may have particular value in the study of the mechanism of platelet interactions with artificial microvascular grafts under perfusion conditions which are relevant to the first moments of flow, when initial platelet deposition occurs.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 26 (1992), S. 1449-1461 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Compliance matching between the host vessel and vascular grafts used for smalldiameter arterial replacements is thought to be important for longterm patency. However, currently available grafts elicit fibroplastic reactions, resulting in decreasing compliance with time after implantation. Bioresorbable prostheses elicit ingrowth of myofibroblasts containing abundant contractile elements. This led us to investigate whether compliance of implanted bioresorbable prostheses decreased as a function of time and if the kinetics of change correlated with the progession of tissue ingrowth. Woven polyglactin 910 prostheses (10 mm × 4 mm i.d.) were implanted into adult NZW rabbit infrarenal aortas and replicates were harvested serially through 8 months. Control grafts were implanted, and immediately resected. Dynamic compliance was measured a t 1-mm axial increments along each explant using a pulse duplicator apparatus which exposed the harvested samples to realistic pulsatile hemodynamics. Compliance was calculated for proximal, mid, and distal segments of each graft and averaged at each time point by grouping into control (zero time, n =3), early (1-4 weeks, n = 13), and late (6-36 weeks, n = 9) explant periods. At late explant periods both proximal and distal compliance were significantly greater than mid graft compliance (p ≤ .02 and p ≤ .03, respectively). There was a significant increase in proximal compliance between early and late explant times (p ≤ .01). Measured increases in mid and distal segment compliance over time did not reach statistical significance. Myofibroblast laden tissue ingrowth into the inner capsule followed macrophage phagocytosis and was nearly complete prior to the time that an increase in compliance was demonstrated. Thus since the major histologic episodes precede the change in compliance, these are not likely initiated by this biomechanical change. We hypothesize the graft resorption coupled with the ingrowth of more compliant tissue likely leads to the increased compliance of the graft material. © 1992 John Wiley & Sons, Inc.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...