Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2010-2014
  • 1990-1994  (4)
  • 1993  (4)
Material
Years
  • 2010-2014
  • 1990-1994  (4)
Year
Keywords
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Archives of gynecology and obstetrics 254 (1993), S. 917-919 
    ISSN: 1432-0711
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Archives of gynecology and obstetrics 254 (1993), S. 1234-1236 
    ISSN: 1432-0711
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1434-601X
    Keywords: 12.20.Fv ; 13.10.+q ; 14.80.Pb
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The cross sections for Bhabha and Møller scattering have been investigated in the energy range 2.1–2.4 MeV using monoenergetic positrons and electrons to search for hypothetical resonances superimposed to the continuum predicted by quantum electro dynamics. Bhabba-to-Mott, Møller-to-Mott and Møller-to-Bhabha cross section ratios were measured. The Bhabha-to-Mott ratios could be determined with statistical errors of typically 1% and remaining systematic errors not exceeding the statistical ones. No resonances in Bhabha scattering were observed. Limits for the intrinsic widths of hypothetical resonances are given. For the first time upper limits are deduced from our data for hypothetical resonances in the Møller scattering cross section in the MeV range. Additionally, Møller-to-Bhabha cross section ratios could be determined with good precision. A good agreement between the experimental and theoretical Møller-to-Bhabha ratios can be stated calling in question the recently predicted existence of series of narrow, unresolvable resonances in the Bhabha scattering cross section.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 347 (1993), S. 491-494 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A flow injection method for the determination of formaldehyde was developed. It is based on its reaction with 3-methyl-2-benzthiazolinone hydrazone (MBTH) to yield a blue formazan anion. Typically 180 μl samples are injected into a buffered carrier stream with a frequency of 30 per hour. This sample line merges with the reagent stream containing MBTH, whereupon an azine is formed. After merging with a second stream containing an acidic solution of FeCl3 as reagent, MBTH is oxidized to an intermediate that attacks the azine yielding the formazan dye with an ɛmax at 635 nm. The method was applied to formaldehyde concentrations in the range from 0.15 mg/l to 15 mg/l. The relative standard deviation was 2.3% for 3 mg/l formaldehyde, and 5.1% for 0.3 mg/l, respectively. Strong reducing agents like nitrite interfere seriously. Out of the family of carbonyl compounds only acetaldehyde and propionaldehyde cause strong positive interference.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...