Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (6)
  • 1960-1964
  • 1995  (6)
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Langmuir 11 (1995), S. 3876-3881 
    ISSN: 1520-5827
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 67 (1995), S. 1538-1540 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: We used local probe techniques to characterize electron beam (e-beam) induced changes in thin oxides on silicon. Primary effects of the 1 nm wide, 300 keV e beam included the formation of positive charges trapped in the SiO2, physical restructuring in the oxide, and deposition of carbonaceous compounds. Charges remained stable in thicker oxides (460 nm) and appeared as changes in the contact potential or microwave response with widths down to 100 nm. In thinner oxides (20 nm) the amount of charge was smaller and less stable; below 7 nm no charge was detected. Physical changes in the oxide, evident as a swelling of irradiated areas, accounted for the etching selectivity of these regions. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    The @journal of physical chemistry 〈Washington, DC〉 99 (1995), S. 7102-7107 
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1437-160X
    Keywords: Osteoarthritis ; Femoral neck fractures ; Osteoporosis ; Glycosaminoglycan composition ; Articular cartilage
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The glycosaminoglycan (GAG) and uronic acid (UA) composition of human hip articular cartilage from patients with femoral neck fractures [assumed osteoporosis (OP); n=12], from patients with osteoarthritis (OA; n=12) and from normal controls (n=9) was determined. Full depth tissue samples from the control and OP groups were analysed from the superior, inferior, anterior and posterior regions, while the OA tissue was from cystic (tissue growing on top of cystic bone lesions) and osteophytic regions, from normal and fibrillated resident cartilage and from regions immediately adjacent to eburnated bone. The total sulphated GAG and UA content was reduced in the inferior region of control cartilage compared to the other regions and the values of all regions of the assumed OP group. Cystic regions and OA cartilage adjacent to the bone also showed lower GAG and UA levels than the other regions. The ratios of chondroitin 6-sulphate (C6S) to chondroitin 4-sulphate (C4S) indicated a similar pattern in the different regions of controls and the patient group with femoral neck fractures (OP group). The cystic and osteophytic cartilage of the OA group exhibited lower C6S/C4S ratios than any other region. The levels of dermatan sulphate (DS) in the cartilage of all regions of the OP and control groups were very similar and low, while the tissues of the OA group contained significantly higher amounts, particularly the cartilage from osteophytes. The previously presumed compositional similarity between normal aged and osteoporotic articular hip cartilage was essentially confirmed in a comparative analysis. Significant changes in GAG and UA composition of OA cartilage from distinct regions was also recorded.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Journal of materials science 30 (1995), S. 63-68 
    ISSN: 1573-4803
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract Creep experiments were conducted on ice crystals in compression to investigate the effects of boundary conditions on a single-slip system deformed in plane strain. Friction at the platens of the deformation apparatus introduces a bending moment which causes a variation in the amount of lattice rotation across the specimen. This is shown to occur in mechanically constrained crystals observed through plane polarized light. Relieving the constraints and minimizing friction at the ice-platen contact leads to the widening of the sample near the specimen-platen interface and the production of ‘tails’ symmetrically disposed about the longitudinal axis of the deformed crystals. This is interpreted to originate from a bending moment in the opposite sense from that obtained in the constrained crystals, resulting from a progressive increase in slip displacement towards the platens where the segments of the slip plane become shorter. When the crystal ends were constrained but allowed to move sideways, a simple shear regime was established in which lattice slip was concentrated in the centre of the crystal.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1434-9949
    Keywords: Frozen Shoulder ; Mobilization under Anesthesia ; Rotator Cuff Tears ; Shoulder Examination
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary In order to evaluate the efficacy of mobilization under anesthesia as a therapy for frozen shoulder, 43 patients with a mean age of 52.8 years were examined after an average time of 4.7 years. Since some authors have been concerned about rotator cuff tears, special attention-using sonography-was paid to rotator cuff lesions. Results: Clinical and sonographic examinations were very similar and showed a perfect recovery in 27 of 37 patients (73.0%). The average time off work after mobilization was 6.2 weeks compared with expected spontaneous recovery of about 30 months. Outcome was worse in patients with previous trauma to their shoulder. In 2 patients (5.4%) the sonography revealed a slight rotator cuff tear, which is not uncommon in 60-year-old persons. Two additional patients (5.4%) underwent shoulder surgery two years after mobilization due to a persistent impingement syndrome and to a supraspinatus-tear. We conclude, that mobilization under anesthesia for frozen shoulder is an effective treatment modality causing little harm.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...