Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (3)
  • 1915-1919
  • 1880-1889
  • 1995  (3)
  • Acoustic schwannoma  (2)
  • Analytical Chemistry and Spectroscopy  (1)
Material
Years
  • 1995-1999  (3)
  • 1915-1919
  • 1880-1889
Year
  • 1995  (3)
Keywords
  • 1
    ISSN: 1432-1920
    Keywords: Internal auditory canal ; Acoustic schwannoma ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Prospective baseline MRI was obtained on 31 patients who had “total” removal of acoustic schwannoma 6 months to 9 years previously. Follow-up MRI was performed after 1–2 years on patients with questionable abnormalities. We found four patterns (1) internal auditory canals (IAC) with nonenhancing soft-tissue strands, possibly scars or distorted residual nerves (8); (2) IAC with marginal enhancement-reactive dura mater (16); (3) IAC with contrast-enhancing globular tissues suggesting residual or recurrent tumour (5); (4) high-signal intensity in the IAC before contrast medium administration, probably related to graft with fat/fascia/muscle (2). Prospective 1-to 2-year follow-up studies were available in 8, 5, and 1 patients in groups 2, 3, and 4 respectively. In group 2, dural enhancement remained unchanged in 5 patients and decreased in 3. In group 3 follow-up showed 1 tumor recurrence (surgically confirmed) and 4 stable abnormalities. In group 4, follow-up in 1 of the 2 patients was stable. In groups 1 and 2, the MRI features correlate well with complete tumor removal. Whether follow-up in these groups is indicated needs to be determined. In group 3 residual or recurrent tumor cannot be excluded. In group 4, grafts may prevent adequate visualization of the IAC.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1920
    Keywords: Key words Internal auditory canal ; Acoustic schwannoma ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Prospective baseline MRI was obtained on 31 patients who had “total” removal of acoustic schwannoma 6 months to 9 years previously. Follow-up MRI was performed after 1–2 years on patients with questionable abnormalities. We found four patterns (1) internal auditory canals (IAC) with nonenhancing soft-tissue strands, possibly scars or distorted residual nerves (8); (2) IAC with marginal enhancement-reactive dura mater (16); (3) IAC with contrast-enhancing globular tissues suggesting residual or recurrent tumour (5); (4) high-signal intensity in the IAC before contrast medium administration, probably related to graft with fat/fascia/muscle (2). Prospective 1- to 2-year follow-up studies were available in 8, 5, and 1 patients in groups 2, 3, and 4 respectively. In group 2, dural enhancement remained unchanged in 5 patients and decreased in 3. In group 3 follow-up showed 1 tumor recurrence (surgically confirmed) and 4 stable abnormalities. In group 4, follow-up in 1 of the 2 patients was stable. In groups 1 and 2, the MRI features correlate well with complete tumor removal. Whether follow-up in these groups is indicated needs to be determined. In group 3 residual or recurrent tumor cannot be excluded. In group 4, grafts may prevent adequate visualization of the IAC.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    X-Ray Spectrometry 24 (1995), S. 307-319 
    ISSN: 0049-8246
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: A self-consistent set of level widths for the K-N7 subshells is assembled using literature experimental data from a variety of spectroscopic methods. In cases where Coster-Kronig processes contribute significantly, the widths differ from the predictions of the atomic single-particle model; in the restricted regions where atomic many-body predictions are available, the agreement is much better. The assembled widths will be useful to Si(Li) spectroscopists who wish to include natural width in the description of spectrometer lineshape; such inclusion will improve accuracy in both fundamental and analytical work. The present database is also of value in identifying where improvements to the currently incomplete knowledge of natural widths are most critical.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...