Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (3)
  • 1930-1934
  • 1998  (2)
  • 1997  (1)
  • 1
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 108 (1998), S. 1377-1389 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: We have performed the rovibrational analysis of the absorption spectrum of 12C2D2 between 5150 and 8000 cm−1, recorded by Fourier transform absorption spectroscopy, and between 12 800 and 16 600 cm−1, recorded by intracavity laser absorption spectroscopy. Respectively 10 and 9 bands are reported for the first time in each range. Improved or new rovibrational parameters were obtained for 34 vibrational levels altogether. The vibrational energies we obtained, together with those reported in the literature, were taken into account to model the vibrational energy pattern in 12C2D2(X˜ 1Σg+). The analysis was performed in successive steps, inferring each time suitable parameters. The 44/55, 11/33, 12/33, and 1/244 quartic order anharmonic resonances were introduced during the procedure. They altogether define vibrational clusters which are characterized by only two dynamical constants of motion, Ns=V1+V2+V3 and k=l4+l5. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-2161
    Keywords: Key words Osteosarcoma ; Distal femur ; MR imaging ; Limb salvage surgery ; Surgical planning
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  Objective. To analyse to what extent MR imaging based decisions were correct in determining the surgical procedure in patients with osteosarcoma of the distal femur. Design. We compared the findings on MR imaging that determined the surgical strategy with the actual surgical findings or histopathological specimen. We assessed to what extent MR images could be used to determine the surgical procedure in patients with osteosarcoma. Patients. Between 1985 and 1992, 34 patients with an osteosarcoma were treated. Two patients had a low-grade osteosarcoma. Thirty-two patients with a high-grade osteosarcoma of the distal femur (17 stage IIB, 15 stage III) were included in this study. Surgical options consisted of either limb salvage surgery or ablative surgery, which included the Van Nes-Borggreve rotationplasty. Limb salvage surgery consisted of extra-articular or transarticular resection, followed by reconstruction. Surgery was planned depending on the local extent of the tumour as depicted on the MR studies, coupled with data from the biopsy, age, patient compliance and histological grade. Follow-up was available in all patients. Nine of 17 patients graded as IIB were alive with an average follow-up of 68 months (range 46–109 months), of whom one has metastases. No local recurrence was encountered. Results. If no tumour involvement on MR imaging was found and this was used as a determining factor, this proved to be correct at subsequent analysis. We found that in eight of 11 cases, when MR images suggested a close relationship between tumour and nerve, an oncologically safe plane could be achieved during surgery. In three, a free plane could not be accomplished, as confirmed at histopathological examination. Hence, when nerve involvement was equivocal on MR imaging we found it valuable to reassess nerve involvement during surgery and reconsider limb salvage surgery. When the decisive factor was the vascular involvement and tumour extension was read as equivocal, it was possible to obtain a oncologically safe plane in six of 13 cases. When comprehensive tumour involvement of any structure was noted pre-operatively, it proved to be correct at histopathological examination, except for one case of assumed vascular involvement that proved to be free. Conclusions. If no tumour involvement of a structure was found on MR imaging and this was used as a determining factor, this proved to be correct. When nerve involvement was equivocal on MR imaging we found it valuable to reassess nerve involvement during surgery and reconsider limb salvage surgery. Extensive tumour involvement of any structure, as shown by MR imaging, could be used correctly as a decisive argument in planning a surgical procedure.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-2161
    Keywords: Key words Magnetic resonance (MR) ; Cartilage ; MR ; MR ; low-field-strength imaging ; MR ; three-dimensional ; MR ; fat-suppression
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  Objective. To identify an optimal pulse sequence for in vitro imaging of hyaline cartilage at 0.5 T. Materials and methods. Twelve holes of varying diameter and depth were drilled in cartilage of two pig knees. These were submerged in saline and scanned with a 0.5-T MR system. Sixteen T1-weighted gradient echo (GE), two T2-weighted GE, and 16 fast spin echo sequences were used, by varying repetition time (TR), echo time (TE), flip angle (FA), echo train length, profile order, and by use of fat saturation. Contrast-to-noise ratios (CNR) of cartilage versus saline solution and cartilage versus subchondral bone were measured. Cartilaginous lesions were evaluated separately by three independent observers. Interobserver variability and correlation between the quantitative and qualitative analyses were calculated. Results. The mean CNRs of two specimens of cartilage versus saline solution ranged from 6.3 (±2.1) to 27.7 (±2.5), and those of cartilage versus subchondral bone from 0.3 (±0.2) to 22.5 (±1.4). The highest CNR was obtained with a T1-weighted spoiled 3D-GE technique (TR 65 ms, TE 11.5 ms, FA 45°). The number of lesions observed per sequence varied from 35 to 69. Observer agreement was fair to good. The T1-weighted spoiled GE sequences with a TR of 65 ms, TE of 11.5 ms and FA of 30° and 45° were significantly superior to the other 34 sequences in the qualitative analysis. Conclusion. T1-weighted spoiled 3D-GE sequences with a TR of 65 ms, a TE of 11.5 ms, and a FA of 30–45° were found to be optimal for in vitro imaging of cartilage at 0.5 T.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...