Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1572-8927
    Keywords: Sodium pertechnetate ; magnesium pertechnetate ; potassium pertechnetate ; osmotic coefficients ; activity coefficients ; solubility ; seawater system ; Pitzer model ; binary parameters ; mixing parameters
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Isopiestic vapor pressure experiments are performed at 25°C with aqueous Mg(TcO4)2 solutions and with ternary mixtures containing various combinations of NaTcO4, Mg(TcO4)2, NaCl, MgCl2, Na2SO4, and MgSO4. The osmotic coefficients of the binary solutions are used to evaluate the binary Pitzer parameters β(0), β(1), and CΦ for Mg(TcO4)2. We previously reported these parameters for NaTcO4. The binary parameters for KTcO4 and Ca(TcO4)2 are evaluated from solubilities of KTcO4 in KCl and CaCl2 solutions, respectively. The mixing parameters Θ TcO 4 − /Cl −, ΨM/TcO 4 − /Cl −, Θ TcO 4 − /SO 4 2− , ΨM/TcO 4 − /SO 4 2− , and ΨNa + /Mg 2+ /TcO4 2− are calculated from either osmotic coefficients or solubilities in the corresponding ternary mixtures. The evaluated set of Pitzer parameters predicts well the activity coefficients and solubilities of KTcO4 in multicomponent systems.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Microbore columns ; Column-switching ; Myristicin ; Serum
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A microbore high-performance liquid chromatographic method with column-switching was developed for the analysis of myristicin from rat serum without prepurification. Deproteinization, fractionation, concentration and separation of analyte were carried out by appropriate switching of columns and using solvent mixtures. The method showed excellent precision, accuracy and speed with a detection limit of 10 ng mL−1 from 25 μL of serum. The total analysis time per sample was 25 min and the coefficients of variation for intra- and inter-assay were less than 1.8%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...