Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2005-2009
  • 2000-2004  (2)
  • 1995-1999
  • 2000  (2)
Material
Years
  • 2005-2009
  • 2000-2004  (2)
  • 1995-1999
Year
  • 1
    ISSN: 1588-2780
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Energy, Environment Protection, Nuclear Power Engineering
    Notes: Abstract True-coincidence summing correction is an essential element in k 0-based NAA1 and becomes important when samples are counted with a high efficiency detector. This may be the case where large detectors are used or where samples are counted in or in the vicinity of the detector in order to achieve low detection limits in conjunction with low-flux reactors. In some laboratories coincidence correction is accomplished by calculating the coincidence correction factors. Since experimental validation of the calculations will reveal only the most significant errors and is a laborious task due to the high number of radionuclides involved, three laboratories decided to compare their calculated coincidence factors. Each laboratory uses a different software package. A comparative performance analysis was made of COINCALC developed at the INW of the University of Gent (implemented in SOLCOI by DSM Research), the software of the IRI, University of Delft, the Netherlands, and the software of the Ecole Polytechnique, Montreal, Canada. The overall approach, data and algorithms were chosen independently by each institute as the software was being developed and, so, the comparison has yielded a number of interesting conclusions. A follow-up investigation of the discrepancies found will probably allow the performance of each program to be improved.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1588-2780
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Energy, Environment Protection, Nuclear Power Engineering
    Notes: Abstract The relative thermal, epithermal and fast neutron fluxes were measured in the inner and outer irradiation sites of three Slowpoke reactors and one Miniature Neutron Source (MNS) reactor by the bare triple monitor method. Using the measured neutron spectrum parameters and a compilation of published k 0 and Q 0 values, activation constants were calculated for the most intense gamma-rays of all nuclides commonly used in NAA. The resulting table of constants can be used to standardize NAA measurements for all elements when combined with relative efficiency measurements and the measurement of the thermal neutron flux with one standard. The observed constancy of the neutron spectra suggests that these activation constants are valid for all 14 Slowpoke and MNS reactors.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...