Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • 2005-2009  (4)
Materialart
Erscheinungszeitraum
Jahr
  • 1
    Digitale Medien
    Digitale Medien
    350 Main Street , Malden , MA 02148-5018 , USA , and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Science Inc
    Journal of cardiovascular electrophysiology 16 (2005), S. 0 
    ISSN: 1540-8167
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: Introduction: This retrospective study investigated whether induced episodes could be used to predict the morphology of future spontaneous atrial episodes. Methods: Eighty-two patients (64 ± 12 years; 77% male; CAD in 60%; left ventricular ejection fraction 45 ± 16%) with a history of atrial tachycardia or atrial fibrillation (AT/AF) were implanted with a dual-chamber implantable cardioverter defibrillator (ICD) and followed for 6 months. A total of 224 episodes of induced and spontaneous AT/AF were classified into type I, II, and III according to the method of Israel et al. and then compared based on average cycle length (CL) and atrial amplitude. Episodes were also grouped as “pace-terminable” or “nonpace-terminable” based on the CL definition of Gillis et al. Results: The analysis of 121 induced episodes (from 80 patients) and 103 spontaneous episodes (from 43 patients) showed that within each arrhythmia type, there were no significant differences in CL or mean amplitude between induced and spontaneous episodes. Additional analysis of patients that had both induced and spontaneous episodes (n = 41) showed 78% had at least one spontaneous episode that matched the induced episode. Fifty-seven percent of spontaneous episodes were considered to be pace-terminable based on CL. Conclusions: Our data suggest that there is no significant difference between induced and spontaneous episodes of AT/AF of the same type. The majority of patients had at least one spontaneous episode of the same type as the induced episode, showing that induced atrial arrhythmias may be useful in predicting the morphology of future spontaneous episodes and in identifying patients potentially benefiting from atrial antitachycardia pacing.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    350 Main Street , Malden , MA 02148-5018 , USA , and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Science Inc
    Journal of cardiovascular electrophysiology 16 (2005), S. 0 
    ISSN: 1540-8167
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    350 Main Street , Malden , MA 02148-5018 , USA and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Science Inc
    Pacing and clinical electrophysiology 28 (2005), S. 0 
    ISSN: 1540-8159
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: This is a report on a patient with an implanted cardioverter defibrillator (ICD) who intentionally underwent magnetic resonance imaging (MRI) of a malignant brain tumor. To avoid inadequate detection of ventricular tachycardia (VT) or ventricular fibrillation (VF), the ICD was inactivated by programming the VT-detection and VT/VF-therapy status off. The patient came through the protocol safely and without any difficulty or discomfort. There was no arrhythmic event. MRI affected neither programmed data nor the function of the ICD system.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    350 Main Street , Malden , MA 02148-5018 , USA and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Science Inc
    Pacing and clinical electrophysiology 28 (2005), S. 0 
    ISSN: 1540-8159
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: Background: Implantation of an additional pace/sense (P/S) lead is commonly used in patients with implantable cardioverter/defibrillators (ICDs) to overcome P/S defects of integrated defibrillation leads (HV-P/S leads). No information is available about the clinical outcome and the incidence of complications in these patients. Methods: Retrospective analysis was performed in 151 patients (125 male, age 54.9 ± 13.6 years, LVEF 48.1 ± 17.8%, CAD in 86 [57%], DCM in 24 [16%], ARVCM in 11 [7%]) who received an additional P/S lead between 1990 and 2002 (54 patients with abdominal and 97 patients with pectoral ICD system). Statistical analysis was done using Kaplan-Meier survival curves. Results: The average follow-up (FU) after implantation of the additional P/S lead was 43 ± 27 months. In total 117 patients [77.5%] remain implanted; 22 patients died due to cardiac-related reasons. After a FU of 23 ± 23 months, 43 patients [28.5%] experienced lead-related problems after implantation of the additional P/S lead: oversensing in 23 [53.5%], insulation defect in 3 [7.0%], fracture in 1 [2.3%], system infection in 4 [9.3%], and defect of the HV-P/S lead in 6 [14.0%] patients. The event-free cumulative survival of the additional P/S lead after 1, 2, and 5 years was 87.0%, 79.8%, and 59.4%, respectively (for pectoral leads: 89.6%, 82.0%, and 60.0%, respectively). Conclusions: Implantation of an additional P/S lead in case of failure of an HV-P/S lead is safe. However, it is associated with a substantial rate of complications during FU. Therefore, extraction of damaged defibrillation leads instead of implantation of P/S leads should be favored.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...