Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2000-2004  (2)
  • 1990-1994  (1)
  • Magnetic resonance imaging  (2)
  • Low PTH  (1)
  • sesquiterpenoids
  • 1
    ISSN: 1437-7799
    Keywords: Key words Lung metastatic calcification ; SPECT ; Dialysis patients ; Pulmonary diffusion capacity ; Low PTH
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Background. Metastatic lung calcification (MLC) is an important complication in long-term dialysis patients, causing respiratory disturbance. We used single photon emission computed tomography (SPECT) in lung (L-SPECT) to detect the distribution of MLC. Methods. L-SPECT with 99mtechnetium hydroxymethylenediphosphonate was performed in 59 patients who had been on maintenance dialysis for more than 5 years. The accumulation count ratios were calculated from counts in the upper lung field (UL), lower lung field (LL), basal lung field along the diaphragm (BASE), and the cardiac pool (POOL). Distribution patterns of radionuclide were classified into four groups. Pulmonary function tests and blood examinations were performed. Results. The median values for UL/POOL, LL/POOL, and BASE/POOL were 1.71, 1.85, and 2.21, respectively. On the SPECT images, 28 patients had positive lung accumulation, versus 7 on the planar images. Patterns and frequency were: group I (none or slight accumulation), 32.2%; group II (accumulation only in the basal lung field), 33.8%; group III (accumulation in the whole lower lung or above), 18.6%; and group IV (diffuse accumulation extending to the whole lung field), 15.2%. Intact osteocalcin level was 6.3 ± 5.3 ng/ml in groups III + IV (large group) vs 94.2 ± 184.3 in groups I + II (small group) (P 〈 0.01). The number of patients with declining diffusion capacity was 20.0% in the large group, vs 5.1% in the small group. All patients in group IV had an intact parathyroid hormone (i-PTH) level of under 65 pg/ml. Conclusions. L-SPECT is very useful for the early detection of MLC, the extension of which may reduce diffusion capacity. Diffuse calcification over the whole lung is considered to be related to a low-turnover bone state concomitant with low PTH level.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Intensive care medicine 18 (1992), S. 371-372 
    ISSN: 1432-1238
    Keywords: Carbon monoxide ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Intracranial abnormalities by magnetic resonance imaging (MRI) in acute carbon monoxide (CO) poisoning have been described in two cases. Edematous bilateral lesions have been demonstrated in the globus pallidus. Findings correspond with the pathological changes described in literature. In our experience MIR is a more sensitive examination compared to serial computed tomography (CT) in acute CO poisoning.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 42 (2000), S. 732-734 
    ISSN: 1432-1920
    Keywords: Key words Glioma, thalamic, bilateral ; Magnetic resonance imaging ; Magnetic resonance spectroscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We report a 63-year-old man who had a rare bilateral thalamic glioma. He complained of difficulty with calculations and had mental deterioration. T1-weighted images revealed bilateral thalamic swelling with homogeneous low signal and no contrast enhancement. The tumour, showing decrease of N-acetylaspartate and the presence of lactate on magnetic resonance spectroscopy, was diagnosed as an astrocytoma by stereotactic biopsy.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...