Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2000-2004
  • 1985-1989  (2)
  • 1970-1974  (1)
  • 1930-1934
  • Chemistry  (2)
  • Diffusing fibre tips  (1)
  • 1
    ISSN: 1435-604X
    Keywords: Photodynamic therapy ; Diffusing fibre tips ; Interstitial light delivery ; Light dosimetry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Physics , Technology
    Notes: Abstract Optimal delivery of light to the tumour is of considerable importance in photodynamic therapy. The most effective way of delivering laser light to the tumour tissue is through an implanted optical fibre. In order to investigate the possible effects taking place at the tips of fibres implanted in tissue, fibres were used to deliver light to human blood and the transmission of light by the blood was measured at different power levels. The maximum power level which could be delivered without charring or coagulation at the fibre tip was measured for five different fibres. Three plane cut fibres and two with 1.5 cm long diffusing tips were studied. Charring and coagulation, which resulted in practically no light being delivered more than 0.5 mm from the fibre tip, were observed at relatively low-output powers (70-130 mW) for all the plane-cut fibres. This is less than the level required to deliver a clinically useful dose in a reasonable time. In contrast, neither charring nor coagulation was observed at the diffusing tips for output powers up to 1.1 W and consequently these should be the fibres of choice for interstitial photodynamic therapy. Observed changes in light transmission through the blood with increasing output power indicate that, for accurate light dosimetry, a means of monitoring delivered light in vivo during photodynamic therapy is essential.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Biopolymers 10 (1971), S. 2499-2508 
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Low-angle light scattering, sedimentation velocity, and intrinsic viscosity measurements have been made on circular and linear forms of lambda (λ) bacteriophage DNA. Available equations, used to relate hydrodynamic parameters of both forms to the molecular weight, give relatively consistent values of particle weights which essentially agree with the light-scattering results. An average molecular weight of (34 ± 3) × 106 for λ DNA was obtained in good agreement with literature values of (31-33) × 106. The linear λ DNA has a larger root-mean-square radius than the circular molecule, when determined by light scattering, but the difference does not appear to be us large as expected from hydrodynamic data. The two forms also show significantly different angular distrbutions of scattered light intensities which agree only qualitatively with those derived from existing theory. The light-scattering results suggest that further experiments and modifications of available theories should be undertaken.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 3 (1989), S. 155-159 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: A new time-of-flight mass analyser compatible with conventional continuous ionization methods is described. A mass resolution at m/z 2000 of m/Δm〉2000 (50% valley) is predicted for the instrument which is presently being prototyped. Sensitivity advantages over scanning instruments are also predicted for this instrument.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...