Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2000-2004  (1)
  • 1970-1974  (3)
Material
Years
Year
Keywords
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    The @journal of organic chemistry 39 (1974), S. 1318-1318 
    ISSN: 1520-6904
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 72 (2001), S. 4331-4336 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The use of synchrotron radiation (SR) as a far- and mid-infrared source in the measurement of photoacoustic Fourier transform infrared spectra of solids is demonstrated for the first time in this work. Initial experiments were performed at beamline U10A at the National Synchrotron Light Source, Brookhaven National Laboratory. For synchrotron photoacoustic spectroscopy to be feasible, it must yield results superior to those obtained with a conventional thermal (Globar®) source; accordingly, SR and Globar® photoacoustic spectra recorded under similar conditions were compared in detail. The intensities of SR far-infrared photoacoustic spectra were found to be consistently greater than the corresponding Globar® spectra. At shorter wavelengths, SR always underfills the effective aperture (or, alternately, sample size); SR is a superior source in a spectral region that is a function of this aperture. The high wave number limit of this region exhibits a power-law dependence on aperture size. This investigation also showed that the entire mid-infrared photoacoustic spectrum is more intense using SR and apertures smaller than approximately 0.5 mm. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    facet.materialart.
    Unknown
    Macomb, Ill., etc. : Periodicals Archive Online (PAO)
    Journal of Geography. 71:6 (1972:Sept.) 354 
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Cell & tissue research 129 (1972), S. 188-195 
    ISSN: 1432-0878
    Keywords: Thymus ; Mouse ; Mitosis ; Circadian rhythm
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary The mitotic and pyknotic indices were calculated over a period of 24 hrs in four different zones of the mouse thymus (Balb/C). Counts were based on 1 micron sections of Epon-embedded tissue. This technique gives a more accurate mitotic index than has been calculated in the past because mitotic figures in the prophase stage are more easily recognizable. Mitotic as well as pyknotic index showed a distinct diurnal rhythm in the subcapsular zone, the rhythm being less distinct towards the medulla, where no significant diurnal fluctuations were demonstrated. It was shown that the index variations could be correlated to significant variations in the mitotic time.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...